IMIT CONTROL SYSTEM

IMIT CONTROL SYSTEM

HYDRAULIC INTERFACE MODULE

WATERLINK WTL6

WATERLINK WTL6 is a hydraulic separation module between

two heat generators powered by different energy sources.

The most typical appliance is that between a thermo-fire-

place (or a thermo-heater) and a gas boiler. When han-

dling heat produced by the biomass source, the module

disables the traditional boiler and activates the 3-way

valve to send hot water to the domestic heating system.

Otherwise the 3-way valve is not enabled, allowing the gas

boiler to meet the required heating needs.

Code

Article

370

181

4

6

0

Supply voltage = 230 V / 50 Hz

Max. absorbed power = 100 W

Water temperature probe = NTC 1 %

Operating water temperature = 0/95°C

Max. water probe temperature = 150°C

Working room temperature = 0/50°C

Storage temperature = 0/60°C

Max. fluid pressure = 3 bar

Protection rating = IPX4D

Certifications = CE

Description

Pack.

561554

WATERLINK WTL6

(1 pump)

Hydraulic module (heating only), with 1 circulator, 1 x 3-way diverter valve,

1 x 34-plate exchanger, complete with cover and FIRE WATER HID control unit.

a.r.

561555

WATERLINK WTL6

(2 pumps)

Hydraulic module (heating only), with 2 circulators, 1 x 3-way diverter valve,

1 x 34-plate exchanger, complete with cover and FIRE WATER HID control unit.

a.r.

WATERCOMBI WTC7

HYDRAULIC INTERFACE MODULE

550

181

6

4

0

WATERCOMBI WTC7 is a hydraulic separation module be-

tween two heat generators powered by different energy

sources, with the production of domestic hot water. The

most typical appliance is that of the combination between

a thermo-fireplace (or a thermo-heater) and a boiler.

When handling heat produced by the biomass source, the

module disables the traditional boiler and sends hot wa-

ter to the domestic heating system or directly to the user

in the event of requesting domestic hot water. Otherwise,

it allows the gas boiler to meet the heating demand and

produce domestic hot water.

Code

Article

Supply voltage = 230 V / 50 Hz

Max. absorbed power = 100 W

Water temperature probe = NTC 1%

Operating water temperature = 0/95°C

Max. water probe temperature = 150°C

Working room temperature = 0/50°C

Storage temperature = 0/60°C

Max. heating fluid pressure = 3 bar

Max. fluid pressure ACS = 6 bar

Protection rating = IPX4D

Certifications = CE

Description

Pack.

S

y

s

t

e

m

s

f

o

r

r

e

n

e

w

a

b

l

e

e

n

e

r

g

y

s

o

u

r

c

e

s

561556

WATERCOMBI

WTC7

(1 pump)

Hydraulic heating and DHW module, with 1 circulator, 1 x 3-way diverter valve,

1 flow switch, 1 x 30-plate exchanger, 1 x 14-plate exchanger, complete with

cover casing and FIRE WATER HID control unit.

a.r.

561557

WATERLINK

WTC7

(2 pumps)

Hydraulic heating and DHW module, with 2 circulators, 1 x 3-way diverter valve,

1 flow switch, 1 x 30-plate exchanger, 1 x 14-plate exchanger, complete with

cover casing and FIRE WATER HID control unit.

a.r.

32