32

Pumps

Pumps

Etaline

PumpMeter, PumpDrive, KSB SuPremE

Etaline Z

Etaline-R

ILN

Control unit

ILNC

Control unit

DN

Q [m

3

/h]

H [m]

p [bar]

T [°C]

DN

Q [m

3

/h]

H [m]

p [bar]

T [°C]

n [rpm]

DN

Q [m

3

/h]

H [m]

p [bar]

T [°C]

n [rpm]

Not available for worldwide sale

Factory-automated

Automation available

DN

Q [m

3

/h]

H [m]

p [bar]

T [°C]

32 - 200

≤ 700

≤ 96

≤ 16

≥ -30 - ≤ +140

Data for 50 Hz operation

Also available for 60 Hz

Description:

Single-stage volute casing pump in in-line design, with magnetless

KSB SuPremE motor of efficiency class IE4/IE5 and PumpDrive variable speed

system; pump shaft and motor shaft are rigidly connected. With KSB SuPremE,

a magnetless synchronous reluctance motor of efficiency class IE4/IE5 to

IEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 or

KSB PumpDrive 2 Eco variable speed system without rotor position sensors.

Motor mounting points in accordance with EN 50347, envelope dimensions in

accordance with DIN V 42673 (07-2011). ATEX-compliant version available.

Applications:

Hot water heating, cooling circuits, air-conditioning, water supply systems,

service water supply systems, industrial recirculation systems

http://shop.ksb.com/catalog/k0/en/product/ES000113

Description:

Single-stage volute casing pump in in-line design as twin pump, with

magnetless KSB SuPremE motor of efficiency class IE4/IE5 and PumpDrive

variable speed system; pump shaft and motor shaft are rigidly connected. An

M12 module (accessory) enables redundant operation of Etaline Z without the

need for a higher-level controller. With KSB SuPremE, a magnetless

synchronous reluctance motor of efficiency class IE4/IE5 to

IEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 or

KSB PumpDrive 2 Eco variable speed system without rotor position sensors.

Motor mounting points in accordance with EN 50347, envelope dimensions in

accordance with DIN V 42673 (07-2011). ATEX-compliant version available.

Applications:

Hot water heating, cooling circuits, air-conditioning, water supply systems,

service water supply systems, industrial recirculation systems

http://shop.ksb.com/catalog/k0/en/product/ES000114

Description:

Vertical close-coupled in-line pump with volute casing and magnetless

KSB SuPremE motor of efficiency class IE4/IE5 and PumpDrive variable speed

system; ATEX-compliant version available.

Applications:

Hot water heating, cooling circuits, air-conditioning, water supply systems,

service water supply systems, industrial recirculation systems

http://shop.ksb.com/catalog/k0/en/product/ES000812

Description:

Vertical in-line centrifugal pump with closed impeller and mechanical seal.

ILNS fitted with an auxiliary vacuum pump, ILNE with ejector. The back pull-

out design allows the impeller to be dismantled without removing the pipes

and the motor. ATEX-compliant version available.

Applications:

Hot-water heating systems, cooling circuits, air-conditioning systems, marine

applications, water and service water supply systems, cleaning systems and

industrial recirculation systems.

http://shop.ksb.com/catalog/k0/en/product/ES000730

Description:

Vertical close-coupled centrifugal pump in in-line design, with electric motor,

closed impeller and mechanical seal. ILNCS fitted with an auxiliary vacuum

pump, ILNCE with ejector. Standardised IEC frame motor. ATEX-compliant

version available.

Applications:

Hot-water heating systems, cooling circuits, air-conditioning systems, marine

applications, water and service water supply systems, cleaning systems and

industrial recirculation systems.

http://shop.ksb.com/catalog/k0/en/product/ES000732

DN

Q [m

3

/h]

H [m]

p [bar]

T [°C]

32 - 200

≤ 1095

≤ 38,5

≤ 16

≥ -30 - ≤ +140

Data for 50 Hz operation

Also available for 60 Hz

150 - 350

≤ 1900

≤ 93

≤ 25

≥ -30 - ≤ +140

Data for 50 Hz operation

Also available for 60 Hz

65 - 400

≤ 3100

≤ 112

≤ 16

≥ -20 - ≤ +70

≤ 3000

Data for 50 Hz operation

Also available for 60 Hz

32 - 125

≤ 370

≤ 112

≤ 16

≥ -20 - ≤ +70

≤ 3000

Data for 50 Hz operation