68
Pumps
Pumps
Not available for worldwide sale
Factory-automated
Automation available
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
≤ 750
≤ 24000
≤ 215
≤ 175
≤ +350
≤ 1800
Description:
Vertical single-stage reactor coolant pump with cast or forged casing, shaft
supported by motor bearing.
Applications:
Reactor coolant recirculation in nuclear power stations.
http://shop.ksb.com/catalog/k0/en/product/ES000146
Description:
Vertical, single-stage reactor coolant pump. Seal-less design with integrated
wet rotor motor and integrated flywheel. Product-lubricated bearings, no oil
supply systems required.
Applications:
Reactor coolant recirculation in generation III+ nuclear power stations.
http://shop.ksb.com/catalog/k0/en/product/ES000848
Description:
Vertical pump set integrated in the reactor containment floor, seal-less pump
with leak-free, low-maintenance wet rotor motor.
Applications:
Reactor coolant recirculation in boiling water reactors.
http://shop.ksb.com/catalog/k0/en/product/ES000150
Description:
Horizontal single-stage double-entry main feed water pump MFWP, cast or
forged variant.
Applications:
Main feed water supply (MFWS) in steam generation systems of nuclear
power stations.
http://shop.ksb.com/catalog/k0/en/product/ES000138
Description:
Vertical pump with integrated motor, single-entry, single- to three-stage.
Suitable for very high inlet pressures and temperatures. Integrated wet
winding motor to VDE. Product-lubricated bearings, no oil supply systems
required. Design to ASME Section 3, KTA, etc.
Applications:
As reactor water clean-up pump in boiling water reactors, reactor coolant
pump in boiling water and pressurised water reactors and recirculation pump
in test facilities.
http://shop.ksb.com/catalog/k0/en/product/ES000855
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
≤ 650
≤ 22000
≤ 111
≤ 155
≤ +350
≤ 1800
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
≤ 600
≤ 9000
≤ 45
≤ 75
≤ +300
≤ 2000
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
n [rpm]
125 - 500
≤ 6500
≤ 1000
≤ 150
≤ +210
≤ 6500
DN
Q [m
3
/h]
H [m]
p [bar]
T [°C]
40 - 600
≤ 7000
≤ 300
≤ 320
≤ +430
Available for 50 Hz and 60 Hz
Higher ratings possible upon request
Available for 50 Hz and 60 Hz
Higher ratings possible upon request
Available for 50 Hz and 60 Hz
Higher ratings possible upon request
Available for 50 Hz and 60 Hz
Higher ratings possible upon request
Data for 50 Hz operation
Also available for 60 Hz