DIM:

25x3.5

32x4.4

40x5.5

50x6.9

63x8.6

75x10.3 90x12.3 110x15.1

d

i

[mm]:

18.0

23.2

29.0

36.2

45.6

54.4

65.4

79.8

kPa/m m/s

0.744 2.999

0.836 3.199

0.934 3.399

1.037 3.599

1.144 3.799

1.256 3.999

1.494 4.399

1.751 4.799

2.027 5.198

2.321 5.598

2.632 5.998

2.962 6.398

3.309 6.798

3.674 7.198

4.056 7.598

4.455 7.998

5.527 8.997

6.704 9.997

7.984 10.997

9.366 11.997

10.849 12.996

Flusso

l/h

l/s

54000 15

57600 16

61200 17

64800 18

68400 19

72000 20

79200 22

86400 24

93600 26

100800 28

108000 30

115200 32

122400 34

129600 36

136800 38

144000 40

162000 45

180000 50

198000 55

216000 60

234000 65

kPa/m m/s

kPa/m

m/s

kPa/m

m/s

kPa/m m/s

kPa/m m/s

10.824 9.105

12.177 9.712

13.603 10.319

15.101 10.926

16.670 11.533

18.309 12.140

kPa/m m/s

4.718 6.454

5.308 6.884

5.929 7.314

6.581 7.744

7.264 8.175

7.977 8.605

9.495 9.465

11.133 10.326

12.888 11.186

14.761 12.047

kPa/m m/s

1.941 4.465

2.184 4.763

2.439 5.061

2.707 5.358

2.987 5.656

3.280 5.954

3.903 6.549

4.576 7.144

5.297 7.740

6.065 8.335

6.881 8.931

7.743 9.526

8.652 10.121

9.607 10.717

10.607 11.312

11.652 11.907

*Fattore di correzione delle perdite di carico per altre temperature

°C

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

Fattore 1.208 1.174 1.144 1.115 1.087 1.060 1.039 1.019 1.000 0.982 0.965 0.954 0.943 0.928 0.923 0.907 0.896 0.878

Uponor Ecoflex | 33