TECHNICAL MANUAL

MaXIMus

Mega slab

68

Product Sizes

135 CM / 53.14”

proDuct tYpoLoGY & SIZeS

120 CM / 47.24”

14.5 MM / 0.57”

* 20 MM / 0.78”

* UPON SPECIAL REQUEST

Product Typology

BODY TYPE

Porcelain Tiles

Porcelain Tiles

Full Body Porcelain Tiles

Full Body Porcelain Tiles

SIZE

POLISHED

(CM)

135X305

120X305

135X305

120X305

NATURAL

14.5MM THICK

20MM THICK

*

TECHNICAL MANUAL

tecHnIcaL SpecIfIcatIonS

BIa-UGL Unpolished

TEST DESCRIPTION

Surface Quality

Length & width

Thickness

Straightness Of Sides

Rectangularity

Surface Flatness: Center Curvature

Surface Flatness: Edge Curvature

Surface Flatness: warpage

water Absorption

Breaking Strength*

Modulus Of Rupture*

Resistance To Surface Abrasion

Resistance To Deep Abrasion

Coefficient Of Linear Thermal Expansion

Resistance To Thermal Shock

Crazing Resistance

Frost Resistance

Resistance To Household Chemicals & Swimming Pool Salts

Resistance To Low Concentrations Acids & Alkalis

Resistance To High Concentrations Acids & Alkalis

Resistance To Staining

Note: This technical specification is applicable only to tiles in choice “A”.

BIa-UGL Polished

TEST DESCRIPTION

Surface Quality

Length & Width

Thickness

Straightness Of Sides

Rectangularity

Surface Flatness: Center Curvature

Surface Flatness: Edge Curvature

Surface Flatness: Warpage

Water Absorption

Breaking Strength*

Modulus Of Rupture*

Resistance To Surface Abrasion

Resistance To Deep Abrasion

Coefficient Of Linear Thermal Expansion

Resistance To Thermal Shock

Crazing Resistance

Frost Resistance

Resistance To Household Chemicals & Swimming Pool Salts

Resistance To Low Concentrations Acids & Alkalis

Resistance To High Concentrations Acids & Alkalis

Resistance To Staining

Note: This technical specification is applicable only to tiles in choice “A”.

STANDARD

TEST METHOD

STANDARD

REQUIREMENTS

RAK CERAMICS SPECIFICATION

14.5 (135X305 CM)

Minimum of 95% of the tiles are free from visible defects

± 0.1%

± 5%

± 0.15%

± 0.15%

± 0.15%

± 0.15%

± 0.15%

≤ 0.1%

≥ 3500 N

≥ 40 N/mm

2

-

≤ 150 mm

3

≤ 7 X 10

-6

/°C

No visible defect

-

No visible damage

Class UA - No visible effect

Class ULA - No visible effect

Class UHA - No visible effect

Min. Class 2 - Stains removed

69

BS EN ISO 10545-2 a minimum of 95% of the tiles are to be free from visible defects

BS EN ISO 10545-2 ± 0.6%

BS EN ISO 10545-2 ± 5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-3 ≤ 0.5%

BS EN ISO 10545-4 ≥ 1300 N

BS EN ISO 10545-4 ≥ 35 N/mm

2

BS EN ISO 10545-7 -

BS EN ISO 10545-6 ≤ 175 mm

3

BS EN ISO 10545-8 Test method available

BS EN ISO 10545-9 Test method available

BS EN ISO 10545-11 -

BS EN ISO 10545-12 Required

BS EN ISO 10545-13 Minimum Class UB

BE EN ISO 10545-13 Manufacturer to state classification

BS EN ISO 10545-13 Test method available

BS EN ISO 10545-14 Test method available

STANDARD

TEST METHOD

STANDARD

REQUIREMENTS

* Test performed using 60X60 cm cut pieces from the slab.

* Thickness is nominal

RAK CERAMICS SPECIFICATION

14.5 (135X305 CM)

Minimum of 95% of the tiles are free from visible defects

± 0.1%

± 5%

± 0.15%

± 0.15%

± 0.15%

± 0.15%

± 0.15%

≤ 0.1%

≥ 3500 N

≥ 40 N/mm

2

-

≤ 150 mm

3

≤ 7 X 10

-6

/°C

No visible defect

-

No visible damage

Class UA - No visible effect

Class ULA - No visible effect

Class UHA - No visible effect

Min. Class 2 - Stains removed

* Test performed using 60X60 cm cut pieces from the slab.

* Thickness is nominal

BS EN ISO 10545-2 a minimum of 95% of the tiles are to be free from visible defects

BS EN ISO 10545-2 ± 0.6%

BS EN ISO 10545-2 ± 5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-2 ± 0.5%

BS EN ISO 10545-3 ≤ 0.5%

BS EN ISO 10545-4 ≥ 1300 N

BS EN ISO 10545-4

≥ 35 N/mm

2

BS EN ISO 10545-7 -

BS EN ISO 10545-6

≤ 175 mm

3

BS EN ISO 10545-8 Test method available

BS EN ISO 10545-9 Test method available

BS EN ISO 10545-11 -

BS EN ISO 10545-12 Required

BS EN ISO 10545-13 Minimum Class UB

BE EN ISO 10545-13 Manufacturer to state classification

BS EN ISO 10545-13 Test method available

BS EN ISO 10545-14 Test method available

>

<

>

<

3

0

5

C

M

/

1

2

0

3

0

5

C

M

/

1

2

0