HP
4 HP
V
220-230-240
Monofase
Hz
50
A
1,0
A
19,6
kW
3,92 - 4,10 - 4,28
5 HP
220-230-240
Monofase
50
1,0
23,7
4,76 - 4,98 - 5,19
8 (12)
0~35
72
53
6 HP
220-230-240
Monofase
50
1,0
26,5
5,41 - 5,66 - 5,90
9 (12)
0~35
74
54
4 HP
380-400-415
Monofase
50
1,0
7,2
4,40 - 4,63 - 4,80
7 (10)
0~35
69
52
5 HP
380-400-415
Monofase
50
1,0
9,2
5,69 - 5,99 - 6,22
8 (12)
0~35
72
53
6 HP
380-400-415
Monofase
50
1,0
9,9
6,15 - 6,47 - 6,72
9 (12)
0~35
74
54
Unità esterne
U-4LZ2E5
U-5LZ2E5
U-6LZ2E5
U-4LZ2E8
U-5LZ2E8
U-6LZ2E8
Alimentazione
Fase
Frequenza
Voltaggio
Capacità raffrescam.
kW
12,1
14,0
15,5
12,1
14,0
15,5
Coefficiente EER
1)
W/W
4,53
4,12
3,88
4,53
4,12
3,88
Assorbimento
A
13,30 - 12,80 - 12,20
16,90 - 16,20 - 15,50
19,60 - 18,70 - 18,00
4,37 - 4,15 - 4,00
5,50 - 5,23 - 5,04
6,44 - 6,12 - 5,89
Consumo in raffresc.
kW
2,67
3,40
4,00
2,67
3,40
4,00
Capacità in riscald.
kW
12,5
16,0
16,5
12,5
16,0
16,5
Coefficiente COP
1)
W/W
5,27
4,71
4,42
5,27
4,71
4,42
Assorbimento
A
12,00 - 11,40 - 11,00
16,90 - 16,20 - 15,50
18,50 - 17,70 - 17,00
3,91 - 3,71 - 3,58
5,50 - 5,22 - 5,03
6,02 - 5,72 - 5,51
Consumo in riscald.
kW
2,37
3,40
3,73
2,37
3,40
3,73
Corrente di spunto
Assorbimento max
Consumo massimo
Numero massimo di unit
à interne collegabili
2)
7 (10)
0~35
69
52
Pressione statica esterna
Pa
m3/min
dB(A)
Portata d'aria
Livello pressione
sonora
Liv. potenza sonora
Dimensioni
Peso netto
Tubi di collegamento
Lunghezza massima tubazioni (totale)
Differenza in elevazione (int/est)
Refrigerante (R32)
Rapporto di capacità unità interna / esterna
(min / max)
3)
Gamma temp.
Raffresc. Min ~ Max
esterne operative
Riscald. Min ~ Max
Raffrescamento
Raffr.(Sil.1/2/3/4)
Riscaldamento
Raffr. / Riscaldam.
AxLxP
Lato liquido
Lato gas
dB(A)
49/47/45/45
50/48/46/45
51/49/47/45
49/47/45/45
50/48/46/45
51/49/47/45
dB(A)
dB(A)
mm
kg
Poll. (mm)
Poll. (mm)
m
m
kg
%
°C
°C
54
69/72
996x980x370
94
3/8 (9,52)
5/8 (15,88)
90 (180)
50 (U.E. in posiz.
superiore) /
40 (U.E. in posiz.
inferiore)
2,7
50~150(130)
-10~52
-20~18
56
70/74
996x980x370
94
3/8 (9,52)
5/8 (15,88)
90 (180)
50 (U.E. in posiz.
superiore) /
40 (U.E. in posiz.
inferiore)
2,7
50~150(130)
-10~52
-20~18
56
72/75
996x980x370
94
3/8 (9,52)
5/8 (15,88)
90 (180)
50 (U.E. in posiz.
superiore) /
40 (U.E. in posiz.
inferiore)
2,7
50~150(130)
-10~52
-20~18
54
69/72
996x980x370
94
3/8 (9,52)
5/8 (15,88)
90 (180)
50 (U.E. in posiz.
superiore) /
40 (U.E. in posiz.
inferiore)
2,7
50~150(130)
-10~52
-20~18
56
70/74
996x980x370
94
3/8 (9,52)
5/8 (15,88)
90 (180)
50 (U.E. in posiz.
superiore) /
40 (U.E. in posiz.
inferiore)
2,7
50~150(130)
-10~52
-20~18
56
72/75
996x980x370
94
3/8 (9,52)
5/8 (15,88)
90 (180)
50 (U.E. in posiz.
superiore) /
40 (U.E. in posiz.
inferiore)
2,7
50~150(130)
-10~52
-20~18
ErP data
4)
SEER
5)
8,50
8,12
7,71
8,50
8,12
7,71
η
s,c
337,0%
321,8%
305,4%
337,0%
321,8%
305,4%
SCOP
5)
5,05
4,61
4,59
5,05
4,61
4,59
η
s,h
199,0%
181,4%
180,6%
199,0%
181,4%
180,6%
1) EER e COP calcolati in base alla direttiva EN 14511. 2) Il numero tra parentesi indica il numero massimo di unità interne collegabili in caso di collegamento di unità interne da 1,5 kW. 3) Il numero tra parentesi
indica il rapporto massimo di capacità interna/esterna consentito in caso di collegamento di unità interne da 1,5 kW. 4) SEER / SCOP e η
s,c
/ η
s,h
sono conformi ai dati di test ErP per le unità interne a cassetta U2
tipo 4 vie 90x90. Certificato Eurovent. 5) SEER / SCOP
è calcolato in base ai valori di efficienza stagionale di raffrescamento/riscaldamento degli ambienti "η" del REGOLAMENTO (UE) 2016/2281 DELLA
COMMISSIONE. SEER, SCOP = (η + Correzione) × PEF.
COMPRESSORE
R2 ROTARY
BLUEFIN
-10 °C
MODALITÀ
RAFFRESCAMENTO
-20 °C
MODALITÀ
RISCALDAMENTO
RIAVVIO
AUTOMATICO
PANASONIC
AC SMART CLOUD
WI-FI OPZIONALE
ANNI
DI GARANZIA SUL
100
INTERNET CONTROL: opzionale.
COMPRESSORE