Unità esterne
U-8ME2E8
U-10ME2E8
U-10ME2E8
U-12ME2E8
U-10ME2E8
U-12ME2E8
U-10ME2E8
U-10ME2E8
U-12ME2E8
U-12ME2E8
U-16ME2E8
U-16ME2E8
Voltaggio
Alimentazione
Fase
Frequenza
Pressione statica esterna (Max)
18 HP
20 HP
22 HP
24 HP
26 HP
28 HP
V
380-400-415
380-400-415
380-400-415
380-400-415
380-400-415
380-400-415
Trifase
Trifase
Trifase
Trifase
Trifase
Trifase
H
z
5
0
5
0
5
0
5
0
5
0
50
Capacità raffrescam.
kW
50,0
56,0
61,5
68,0
73,0
78,5
Coefficiente EER
1)
W/W
4,55
4,38
4,13
3,93
3,80
3,69
Assorbimento
A
18,20 - 17,30 - 16,60
21,40 - 20,30 - 19,60
24,30 - 23,10 - 22,30
28,00 - 26,60 - 25,60
31,70 - 30,10 - 29,00
34,80 - 33,10 - 31,90
Consumo in raffresc.
kW
11,00
12,80
14,90
17,30
19,20
21,30
Capacità in riscald.
kW
56,0
63,0
69,0
76,5
81,5
87,5
Coefficiente COP
1)
W/W
4,96
4,77
4,76
4,69
4,55
4,56
Assorbimento
A
18,70 - 17,70 - 17,10
22,00 - 20,90 - 20,20
23,90 - 22,70 - 21,90
26,60 - 25,30 - 24,40
29,90 - 28,40 - 27,40
31,70 - 30,10 - 29,00
Consumo in riscald.
kW
11,30
13,20
14,50
16,30
17,90
19,20
Corrente di spunto
A
2,00
2,00
P
a
8
0
80
m3/min
448
448
dB(A)
58,5
59,0
dB(A)
55,5
56,0
dB(A)
79,5
80,0
2,00
80
456
61,0
58,0
82,0
1842 x 2010
x1000/480
5/8 (15,88) /
3/4 (19,05)
1-1/8 (28,58) /
1-1/4 (31,75)
1/4 (6,35)
13,90 / 29,0232
50 ~ 130 (200)
-10~+52
-25~+18
34 HP
380-400-415
Trifase
2,00
80
464
62,0
59,0
83,0
1842 x 2420
x1000/540
5/8 (15,88) /
3/4 (19,05)
1-1/8 (28,58) /
1-1/4 (31,75)
1/4 (6,35)
16,60 / 34,6608
50 ~ 130 (200)
-10~+52
-25~+18
36 HP
380-400-415
Trifase
3,00
80
456
62,5
59,5
83,5
1842 x 2010
x1000/535
x1000/585
Portata d'aria
Livello pressione
sonora
Liv. potenza sonora
Dimensioni /
Peso netto
Tubi di
collegamento
2)
Mod. normale
Mod. silenziosa
Mod. normale
AxLxP
Lato liquido
Lato gas
Bilanciamento
3,00
80
464
63,5
60,5
84,5
mm / kg
Poll. (mm)
Poll. (mm)
Poll (mm)
1842x1600
1842x1600
x1000/420
x1000/420
1842 x 2420
Refrigerante (R410A) / CO
2
Eq
Rapporto di capacità unità interna / esterna (min /
5/8 (15,88) /
3/4 (19,05)
1-1/8 (28,58) /
1-1/4 (31,75)
1/4 (6,35)
11,20 / 23,3856
50 ~ 130 (200)
-10~+52
-25~+18
30 HP
380-400-415
Trifase
5/8 (15,88) /
3/4 (19,05)
1-1/8 (28,58) /
1-1/4 (31,75)
1/4 (6,35)
11,20 / 23,3856
50 ~ 130 (200)
-10~+52
-25~+18
32 HP
380-400-415
Trifase
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
13,90 / 29,0232
50 ~ 130 (200)
-10~+52
-25~+18
38 HP
380-400-415
Trifase
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
16,60 / 34,6608
50 ~ 130 (200)
-10~+52
-25~+18
40 HP
380-400-415
Trifase
Gamma temp.
esterne operative
Alimentazione
Corrente di spunto
Raffresc. Min ~ Max
Riscald. Min ~ Max
Voltaggio
Fase
Frequenza
°C
°C
V
Hz
A
Pa
50
50
50
50
50
50
kg / T
max)
3)
Unità esterne
U-14ME2E8
U-16ME2E8
U-10ME2E8
U-12ME2E8
U-10ME2E8
U-12ME2E8
U-16ME2E8
U-16ME2E8
U-12ME2E8
U-12ME2E8
U-12ME2E8
U-12ME2E8
U-12ME2E8
U-12ME2E8
U-16ME2E8
U-16ME2E8
Capacità raffrescam.
kW
85,0
90,0
96,0
101,0
107,0
113,0
Coefficiente EER
1)
W/W
3,68
3,52
4,05
3,95
3,84
3,75
Assorbimento
A
38,60 - 36,60 - 35,30
42,30 - 40,20 - 38,70
38,70 - 36,80 - 35,50
41,40 - 39,30 - 37,90
46,10 - 43,80 - 42,20
49,20 - 46,70 - 45,00
Consumo in raffresc.
kW
23,10
25,60
23,70
25,60
27,90
30,10
Capacità in riscald.
kW
95,0
100,0
108,0
113,0
119,0
127,0
Coefficiente COP
1)
W/W
4,48
4,42
4,72
4,73
4,61
4,57
Assorbimento
A
35,40 - 33,60 - 32,40
37,70 - 35,80 - 34,60
37,80 - 35,90 - 34,60
39,00 - 37,10 - 35,80
42,60 - 40,50 - 39,00
45,90 - 43,60 - 42,00
Consumo in riscald.
kW
21,20
22,60
22,90
23,90
25,80
27,80
Pressione statica esterna (Max)
4,00
80
696
64,5
61,5
85,5
4,00
4,00
80
80
3,00
80
688
63,0
60,0
84,0
1842 x 3250
x1000/750
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
22,20 / 46,3536
50 ~ 130 (200)
-10~+52
-25 ~ +18
3,00
80
696
64,0
61,0
85,0
1842 x 3660
x1000/810
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50 ~ 130 (200)
-10~+52
-25 ~ +18
4,00
80
688
64,0
61,0
85,0
1842 x 3250
x1000/795
x1000/855
Portata d'aria
Livello pressione
sonora
Liv. potenza sonora
Dimensioni /
Peso netto
Tubi di
collegamento
2)
Mod. normale
Mod. silenziosa
Mod. normale
AxLxP
Lato liquido
Lato gas
Bilanciamento
m3/min
464
464
dB(A)
63,5
64,0
dB(A)
60,5
61,0
dB(A)
84,5
85,0
mm / kg
Poll. (mm)
Poll. (mm)
Poll (mm)
1842x2420
1842x2420
x1000/630
x1000/630
1842 x 3660
Refrigerante (R410A) / CO
2
Eq
Rapporto di capacità unità interna / esterna (min / max)
3)
Gamma temp.
Raffresc. Min ~ Max °C
esterne operative
Riscald. Min ~ Max °C
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
16,60 / 34,6608
50 ~ 130 (200)
-10~+52
-25 ~ +18
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
16,60 / 34,6608
50 ~ 130 (200)
-10~+52
-25 ~ +18
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
22,20 / 46,3536
50 ~ 130 (200)
-10~+52
-25 ~ +18
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 46,3536
50 ~ 130 (200)
-10~+52
-25 ~ +18
kg / T
120
equivalente della tubazione più lunga supera i 90 m, aumentare le dimensioni dei tubi principali di 1 grado per i tubi del gas e i tubi del liquido). 3) Se sono soddisfatte le seguenti condizioni, la portata effettiva
è
superiore al 130% e inferiore al 200%: A. Rispettare il numero limitato di unità interne collegabili. B. Il limite inferiore di operatività con temperatura esterna di riscaldamento è limitato a -10 °C WB (standard
-25 °C WB). C. Il funzionamento simultaneo è limitato a meno del 130% delle unità interne collegabili.