R410A

SISTEMI VRF

42 HP

44 HP

46 HP

48 HP

50 HP

52 HP

Unità esterne

U-10ME2E8

U-12ME2E8

U-14ME2E8

U-16ME2E8

U-10ME2E8

U-12ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-12ME2E8

U-12ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-12ME2E8

U-12ME2E8

U-16ME2E8

U-16ME2E8

Voltaggio

Alimentazione

Fase

Frequenza

Pressione statica esterna (Max)

V

380-400-415

380-400-415

380-400-415

380-400-415

380-400-415

380-400-415

Trifase

Trifase

Trifase

Trifase

Trifase

Trifase

H

z

5

0

5

0

5

0

5

0

5

0

50

Capacità raffrescam.

kW

118,0

124,0

130,0

135,0

140,0

145,0

Coefficiente EER

1)

W/W

3,69

3,62

3,62

3,52

3,87

3,82

Assorbimento

A

52,80 - 50,20 - 48,40

56,00 - 53,20 - 51,30

59,90 - 56,90 - 54,90

63,40 - 60,20 - 58,10

59,10 - 56,20 - 54,20

62,10 - 59,00 - 56,80

Consumo in raffresc.

kW

32,00

34,30

35,90

38,40

36,20

38,00

Capacità in riscald.

kW

132,0

138,0

145,0

150,0

155,0

160,0

Coefficiente COP

1)

W/W

4,49

4,50

4,46

4,42

4,65

4,66

Assorbimento

A

49,10 - 46,60 - 44,90

50,70 - 48,20 - 46,40

54,30 - 51,50 - 49,70

56,60 - 53,80 - 51,80

55,00 - 52,20 - 50,40

56,60 - 53,80 - 51,90

Consumo in riscald.

kW

29,40

30,70

32,50

33,90

33,30

34,30

Corrente di spunto

A

5,00

5,00

P

a

8

0

80

m3/min

688

696

dB(A)

65,0

65,5

dB(A)

62,0

62,5

dB(A)

86,0

86,5

6,00

80

696

65,5

62,5

86,5

1842 x 3660

x1000/900

x1000/945

x1000/945

x1000/1065

x1000/1125

Portata d'aria

Livello pressione

sonora

Liv. potenza sonora

Dimensioni /

Peso netto

Tubi di

collegamento

2)

Mod. normale

Mod. silenziosa

Mod. normale

AxLxP

Lato liquido

Lato gas

Bilanciamento

6,00

80

696

66,0

63,0

87,0

5,00

80

920

65,5

62,5

86,5

5,00

80

928

66,0

63,0

87,0

mm / kg

Poll. (mm)

Poll. (mm)

Poll (mm)

1842 x 3250

x1000/840

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

22,20 / 51,9912

50 ~ 130 (200)

-10~+52

-25~+18

54 HP

380-400-415

Trifase

1842 x 3660

1842 x 3660

1842 x 4490

1842 x 4900

Refrigerante (R410A) / CO

2

Eq

Rapporto di capacità unità interna / esterna (min /

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50 ~ 130 (200)

-10~+52

-25~+18

56 HP

380-400-415

Trifase

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50 ~ 130 (200)

-10~+52

-25~+18

58 HP

380-400-415

Trifase

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50 ~ 130 (200)

-10~+52

-25~+18

60 HP

380-400-415

Trifase

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

30,50 / 63,6840

50 ~ 130 (200)

-10~+52

-25~+18

62 HP

380-400-415

Trifase

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

33,20 / 69,3216

50 ~ 130 (200)

-10~+52

-25~+18

64 HP

380-400-415

Trifase

kg / T

max)

3)

Gamma temp.

esterne operative

Alimentazione

Corrente di spunto

Raffresc. Min ~ Max

Riscald. Min ~ Max

Voltaggio

Fase

Frequenza

°C

°C

V

Hz

A

Pa

50

50

50

50

50

50

Unità esterne

U-10ME2E8

U-12ME2E8

U-10ME2E8

U-12ME2E8

U-14ME2E8

U-16ME2E8

U-12ME2E8

U-12ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

Capacità raffrescam.

kW

151,0

156,0

162,0

168,0

174,0

180,0

Coefficiente EER

1)

W/W

3,75

3,71

3,65

3,60

3,60

3,52

Assorbimento

A

66,60 - 63,20 - 60,90

68,80 - 65,30 - 63,00

73,30 - 69,70 - 67,10

77,10 - 73,30 - 70,60

79,80 - 75,80 - 73,00

84,60 - 80,30 - 77,40

Consumo in raffresc.

kW

40,30

42,10

44,40

46,70

48,30

51,20

Capacità in riscald.

kW

169,0

175,0

182,0

189,0

195,0

201,0

Coefficiente COP

1)

W/W

4,56

4,56

4,47

4,47

4,45

4,42

Assorbimento

A

61,90 - 58,80 - 56,70

63,40 - 60,20 - 58,10

68,00 - 64,60 - 62,20

70,60 - 67,10 - 64,70

73,10 - 69,50 - 67,00

76,00 - 72,20 - 69,60

Consumo in riscald.

kW

37,10

38,40

40,70

42,30

43,80

45,50

Pressione statica esterna (Max)

6,00

6,00

80

80

7,00

80

920

66,5

63,5

87,5

1842x4490

x1000/1155

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

30,50 / 63,6840

50 ~ 130 (200)

-10~+52

-25 ~ +18

7,00

80

928

67,0

64,0

88,0

1842x4900

x1000/1215

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

33,20 / 69,3216

50 ~ 130 (200)

-10~+52

-25 ~ +18

8,00

80

928

67,0

64,0

88,0

1842x4900

x1000/1260

3/4 (19,05) /

7/8 (22,22)

1-5/8 (41,28) /

1-3/4 (44,45)

1/4 (6,35)

33,20 / 69,3216

50 ~ 130 (200)

-10~+52

-25 ~ +18

8,00

80

928

67,0

64,0

88,0

1842x4900

x1000/1260

3/4 (19,05) /

7/8 (22,22)

1-5/8 (41,28) /

1-3/4 (44,45)

1/4 (6,35)

33,20 / 69,3216

50 ~ 130 (200)

-10~+52

-25 ~ +18

Portata d'aria

Livello pressione

sonora

Liv. potenza sonora

Dimensioni /

Peso netto

Tubi di

collegamento

2)

Mod. normale

Mod. silenziosa

Mod. normale

AxLxP

Lato liquido

Lato gas

Bilanciamento

m3/min

920

928

dB(A)

66,0

66,5

dB(A)

63,0

63,5

dB(A)

87,0

87,5

mm / kg

Poll. (mm)

Poll. (mm)

Poll (mm)

1842x4490

x1000/1110

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

30,50 / 63,6840

50 ~ 130 (200)

-10~+52

-25 ~ +18

1842x4900

x1000/1170

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

33,20 / 69,3216

50 ~ 130 (200)

-10~+52

-25 ~ +18

Refrigerante (R410A) / CO

2

Eq

Rapporto di capacità unità interna / esterna (min / max)

3)

Gamma temp.

Raffresc. Min ~ Max °C

esterne operative

Riscald. Min ~ Max °C

kg / T

I dati sono di riferimento. 1) EER e COP calcolati in base alla normativa EN14511. 2) Diametro delle tubazioni inferiore a 90 m per l'unità interna finale / superiore a 90 m per l'unità interna finale (se la lunghezza

equivalente della tubazione più lunga supera i 90 m, aumentare le dimensioni dei tubi principali di 1 grado per i tubi del gas e i tubi del liquido). 3) Se sono soddisfatte le seguenti condizioni, la portata effettiva è

superiore al 130% e inferiore al 200%: A. Rispettare il numero limitato di unità interne collegabili. B. Il limite inferiore di operativit

à con temperatura esterna di riscaldamento è limitato a -10 °C WB (standard

-25 °C WB). C. Il funzionamento simultaneo è limitato a meno del 130% delle unità interne collegabili.

121

Condizioni di operatività: Raffrescamento interno 27 °C DB / 19 °C WB. Raffrescamento esterno 35 °C DB / 24 °C WB. Riscaldamento interno 20 °C DB. Riscaldamento esterno 7 °C DB / 6 °C WB. (DB: Bulbo secco; WB: Bulbo umido). Specifiche soggette a

modifiche senza preavviso. Per informazioni dettagliate su ErP / Etichettatura energetica, visitare i nostri siti web www.aircon.panasonic.eu o www.ptc.panasonic.eu.