42 HP
44 HP
46 HP
48 HP
50 HP
52 HP
Unità esterne
U-10ME2E8
U-12ME2E8
U-14ME2E8
U-16ME2E8
U-10ME2E8
U-12ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-12ME2E8
U-12ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-12ME2E8
U-12ME2E8
U-16ME2E8
U-16ME2E8
Voltaggio
Alimentazione
Fase
Frequenza
Pressione statica esterna (Max)
V
380-400-415
380-400-415
380-400-415
380-400-415
380-400-415
380-400-415
Trifase
Trifase
Trifase
Trifase
Trifase
Trifase
H
z
5
0
5
0
5
0
5
0
5
0
50
Capacità raffrescam.
kW
118,0
124,0
130,0
135,0
140,0
145,0
Coefficiente EER
1)
W/W
3,69
3,62
3,62
3,52
3,87
3,82
Assorbimento
A
52,80 - 50,20 - 48,40
56,00 - 53,20 - 51,30
59,90 - 56,90 - 54,90
63,40 - 60,20 - 58,10
59,10 - 56,20 - 54,20
62,10 - 59,00 - 56,80
Consumo in raffresc.
kW
32,00
34,30
35,90
38,40
36,20
38,00
Capacità in riscald.
kW
132,0
138,0
145,0
150,0
155,0
160,0
Coefficiente COP
1)
W/W
4,49
4,50
4,46
4,42
4,65
4,66
Assorbimento
A
49,10 - 46,60 - 44,90
50,70 - 48,20 - 46,40
54,30 - 51,50 - 49,70
56,60 - 53,80 - 51,80
55,00 - 52,20 - 50,40
56,60 - 53,80 - 51,90
Consumo in riscald.
kW
29,40
30,70
32,50
33,90
33,30
34,30
Corrente di spunto
A
5,00
5,00
P
a
8
0
80
m3/min
688
696
dB(A)
65,0
65,5
dB(A)
62,0
62,5
dB(A)
86,0
86,5
6,00
80
696
65,5
62,5
86,5
1842 x 3660
x1000/900
x1000/945
x1000/945
x1000/1065
x1000/1125
Portata d'aria
Livello pressione
sonora
Liv. potenza sonora
Dimensioni /
Peso netto
Tubi di
collegamento
2)
Mod. normale
Mod. silenziosa
Mod. normale
AxLxP
Lato liquido
Lato gas
Bilanciamento
6,00
80
696
66,0
63,0
87,0
5,00
80
920
65,5
62,5
86,5
5,00
80
928
66,0
63,0
87,0
mm / kg
Poll. (mm)
Poll. (mm)
Poll (mm)
1842 x 3250
x1000/840
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
22,20 / 51,9912
50 ~ 130 (200)
-10~+52
-25~+18
54 HP
380-400-415
Trifase
1842 x 3660
1842 x 3660
1842 x 4490
1842 x 4900
Refrigerante (R410A) / CO
2
Eq
Rapporto di capacità unità interna / esterna (min /
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50 ~ 130 (200)
-10~+52
-25~+18
56 HP
380-400-415
Trifase
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50 ~ 130 (200)
-10~+52
-25~+18
58 HP
380-400-415
Trifase
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50 ~ 130 (200)
-10~+52
-25~+18
60 HP
380-400-415
Trifase
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
30,50 / 63,6840
50 ~ 130 (200)
-10~+52
-25~+18
62 HP
380-400-415
Trifase
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
33,20 / 69,3216
50 ~ 130 (200)
-10~+52
-25~+18
64 HP
380-400-415
Trifase
kg / T
max)
3)
Gamma temp.
esterne operative
Alimentazione
Corrente di spunto
Raffresc. Min ~ Max
Riscald. Min ~ Max
Voltaggio
Fase
Frequenza
°C
°C
V
Hz
A
Pa
50
50
50
50
50
50
Unità esterne
U-10ME2E8
U-12ME2E8
U-10ME2E8
U-12ME2E8
U-14ME2E8
U-16ME2E8
U-12ME2E8
U-12ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
Capacità raffrescam.
kW
151,0
156,0
162,0
168,0
174,0
180,0
Coefficiente EER
1)
W/W
3,75
3,71
3,65
3,60
3,60
3,52
Assorbimento
A
66,60 - 63,20 - 60,90
68,80 - 65,30 - 63,00
73,30 - 69,70 - 67,10
77,10 - 73,30 - 70,60
79,80 - 75,80 - 73,00
84,60 - 80,30 - 77,40
Consumo in raffresc.
kW
40,30
42,10
44,40
46,70
48,30
51,20
Capacità in riscald.
kW
169,0
175,0
182,0
189,0
195,0
201,0
Coefficiente COP
1)
W/W
4,56
4,56
4,47
4,47
4,45
4,42
Assorbimento
A
61,90 - 58,80 - 56,70
63,40 - 60,20 - 58,10
68,00 - 64,60 - 62,20
70,60 - 67,10 - 64,70
73,10 - 69,50 - 67,00
76,00 - 72,20 - 69,60
Consumo in riscald.
kW
37,10
38,40
40,70
42,30
43,80
45,50
Pressione statica esterna (Max)
6,00
6,00
80
80
7,00
80
920
66,5
63,5
87,5
1842x4490
x1000/1155
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
30,50 / 63,6840
50 ~ 130 (200)
-10~+52
-25 ~ +18
7,00
80
928
67,0
64,0
88,0
1842x4900
x1000/1215
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
33,20 / 69,3216
50 ~ 130 (200)
-10~+52
-25 ~ +18
8,00
80
928
67,0
64,0
88,0
1842x4900
x1000/1260
3/4 (19,05) /
7/8 (22,22)
1-5/8 (41,28) /
1-3/4 (44,45)
1/4 (6,35)
33,20 / 69,3216
50 ~ 130 (200)
-10~+52
-25 ~ +18
8,00
80
928
67,0
64,0
88,0
1842x4900
x1000/1260
3/4 (19,05) /
7/8 (22,22)
1-5/8 (41,28) /
1-3/4 (44,45)
1/4 (6,35)
33,20 / 69,3216
50 ~ 130 (200)
-10~+52
-25 ~ +18
Portata d'aria
Livello pressione
sonora
Liv. potenza sonora
Dimensioni /
Peso netto
Tubi di
collegamento
2)
Mod. normale
Mod. silenziosa
Mod. normale
AxLxP
Lato liquido
Lato gas
Bilanciamento
m3/min
920
928
dB(A)
66,0
66,5
dB(A)
63,0
63,5
dB(A)
87,0
87,5
mm / kg
Poll. (mm)
Poll. (mm)
Poll (mm)
1842x4490
x1000/1110
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
30,50 / 63,6840
50 ~ 130 (200)
-10~+52
-25 ~ +18
1842x4900
x1000/1170
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
33,20 / 69,3216
50 ~ 130 (200)
-10~+52
-25 ~ +18
Refrigerante (R410A) / CO
2
Eq
Rapporto di capacità unità interna / esterna (min / max)
3)
Gamma temp.
Raffresc. Min ~ Max °C
esterne operative
Riscald. Min ~ Max °C
kg / T
I dati sono di riferimento. 1) EER e COP calcolati in base alla normativa EN14511. 2) Diametro delle tubazioni inferiore a 90 m per l'unità interna finale / superiore a 90 m per l'unità interna finale (se la lunghezza
equivalente della tubazione più lunga supera i 90 m, aumentare le dimensioni dei tubi principali di 1 grado per i tubi del gas e i tubi del liquido). 3) Se sono soddisfatte le seguenti condizioni, la portata effettiva è
superiore al 130% e inferiore al 200%: A. Rispettare il numero limitato di unità interne collegabili. B. Il limite inferiore di operativit
à con temperatura esterna di riscaldamento è limitato a -10 °C WB (standard
-25 °C WB). C. Il funzionamento simultaneo è limitato a meno del 130% delle unità interne collegabili.
121
Condizioni di operatività: Raffrescamento interno 27 °C DB / 19 °C WB. Raffrescamento esterno 35 °C DB / 24 °C WB. Riscaldamento interno 20 °C DB. Riscaldamento esterno 7 °C DB / 6 °C WB. (DB: Bulbo secco; WB: Bulbo umido). Specifiche soggette a
modifiche senza preavviso. Per informazioni dettagliate su ErP / Etichettatura energetica, visitare i nostri siti web www.aircon.panasonic.eu o www.ptc.panasonic.eu.