R410A

ECOi EX Serie ME2 a 2 tubi, combinazione di modelli salvaspazio da 22 a 80 HP

Unità esterne

U-10ME2E8

U-12ME2E8

U-10ME2E8

U-12ME2E8

U-14ME2E8

U-16ME2E8

U-14ME2E8

U-12ME2E8

U-12ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-20ME2E8

Voltaggio

Alimentazione

Fase

Frequenza

22 HP

24 HP

26 HP

28 HP

30 HP

32 HP

34 HP

V

380-400-415 380-400-415 380-400-415 380-400-415 380-400-415 380-400-415 380-400-415

Trifase

Trifase

Trifase

Trifase

Trifase

Trifase

Trifase

H

z

5

0

5

0

5

0

5

0

5

0

5

0

50

A

2,00

2,00

3,00

3,00

4,00

4,00

4,00

P

a

8

0

8

0

8

0

8

0

8

0

8

0

80

m3/min

456

464

456

464

464

464

637

Capacità raffrescam.

kW

61,5

68,0

73,0

78,5

85,0

90,0

96,0

Coefficiente EER

1)

W/W

4,13

3,93

3,80

3,69

3,68

3,52

3,56

Coefficiente SEER

2)

6,90

6,86

6,62

6,60

6,88

6,55

7,21

Assorbimento

A

24,30-23,10-22,30

28,00-26,60-25,60

31,70-30,10-29,00

34,80-33,10-31,90

38,60-36,60-35,30

42,30-40,20-38,70

44,10-41,90-40,40

Consumo in raffresc.

kW

14,90

17,30

19,20

21,30

23,10

25,60

27,00

Capacità in riscald.

kW

69,0

76,5

81,5

87,5

95,0

100,0

108,0

Coefficiente COP

1)

W/W

4,76

4,69

4,55

4,56

4,48

4,42

4,17

Coefficiente SCOP

2)

4,53

4,78

4,16

4,29

4,13

4,09

4,14

Assorbimento

A

23,90-22,70-21,90

26,60-25,30-24,40

29,90-28,40-27,40

31,70-30,10-29,00

35,40-33,60-32,40

37,70-35,80-34,60

42,80-40,60-39,20

Consumo in riscald.

kW

14,50

16,30

17,90

19,20

21,20

22,60

25,90

Corrente di spunto

Pressione statica esterna (Max)

Portata d'aria

Liv. pressione sonora

Liv. potenza sonora

Dimensioni /

Peso netto

Tubi di

collegamento

3)

Mod. Normale/ Sil.

Modalità Normale

AxLxP

Lato liquido

Lato gas

Bilanciamento

dB(A)

dB(A)

mm / kg

Poll. (mm)

Poll. (mm)

Poll (mm)

61,0 / 58,0

82,0

1842 x 2010

x1000/480

5/8 (15,88) /

3/4 (19,05)

1-1/8 (28,58) /

1-1/4 (31,75)

1/4 (6,35)

13,90 / 23,3856

50 ~ 130 (200)

-10~+52

-25~+18

36 HP

380-400-415

Trifase

62,0 / 59,0

83,0

1842 x 2420

x1000/540

5/8 (15,88) /

3/4 (19,05)

1-1/8 (28,58) /

1-1/4 (31,75)

1/4 (6,35)

16,60 / 34,6608

50 ~ 130 (200)

-10~+52

-25~+18

38 HP

380-400-415

Trifase

62,5 / 59,5

83,5

1842 x 2010

x1000/525

x1000/585

63,5 / 60,5

84,5

63,5 / 60,5

84,5

1842 x 2420

x1000/630

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

16,60 / 34,6608

50 ~ 130 (200)

-10~+52

-25~+18

44 HP

380-400-415

Trifase

64,0 / 61,0

85,0

1842 x 2420

x1000/630

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

16,60 / 34,6608

50 ~ 130 (200)

-10~+52

-25~+18

46 HP

380-400-415

Trifase

63,0 / 60,0

84,0

1842 x 2780

x1000/690

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

17,80 / 37,1664

50 ~ 130 (200)

-10~+52

-25~+18

48 HP

380-400-415

Trifase

1842 x 2420

Refrigerante (R410A) / CO

2

Eq

Rapporto di capacità unità interna / esterna (min /

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

13,90 / 29,0232

50 ~ 130 (200)

-10~+52

-25~+18

40 HP

380-400-415

Trifase

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

16,60 / 34,6608

50 ~ 130 (200)

-10~+52

-25~+18

42 HP

380-400-415

Trifase

kg / T

max)

4)

Gamma temp.

esterne operative

Alimentazione

Raffresc. Min ~ Max

Riscald. Min ~ Max

Voltaggio

Fase

Frequenza

°C

°C

V

Hz

A

Pa

Unità esterne

U-16ME2E8

U-18ME2E8

U-20ME2E8

U-10ME2E8

U-12ME2E8

U-14ME2E8

U-16ME2E8

U-20ME2E8

U-20ME2E8

U-20ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

Capacità raffrescam.

kW

101,0

107,0

113,0

118,0

124,0

130,0

135,0

Coefficiente EER

1)

W/W

3,42

3,42

3,34

3,69

3,62

3,62

3,52

Coefficiente SEER

2)

6,86

7,32

7,16

6,57

6,60

6,70

6,55

Assorbimento

A

47,70-45,30-43,70

50,60-48,10-46,30

54,10-51,40-49,50

52,80-50,20-48,40

56,00-53,20-51,30

59,90-56,90-54,90

63,40-60,20-58,10

Consumo in raffresc.

kW

25,9

31,3

33,8

32,0

34,3

35,9

38,4

Capacità in riscald.

kW

113,0

119,0

127,0

132,0

138,0

145,0

150,0

Coefficiente COP

1)

W/W

4,14

4,13

3,92

4,49

4,50

4,46

4,42

Coefficiente SCOP

2)

4,06

4,14

4,13

4,11

4,21

4,12

4,09

Assorbimento

A

44,60-42,40-40,80

47,10-44,70-43,10

52,40-49,80-48,00

49,10-46,60-44,90

50,70-48,20-46,40

54,30-51,50-49,7

56,60-53,80-51,8

Consumo in riscald.

kW

27,30

28,80

32,40

29,40

30,70

32,50

33,90

Corrente di spunto

50

50

50

50

50

50

50

4,00

4,00

4,00

5,00

5,00

6,00

6,00

80

80

80

80

80

80

80

Pressione statica esterna (Max)

Portata d'aria

Liv. pressione sonora

Liv. potenza sonora

Dimensioni /

Peso netto

Tubi di

collegamento

3)

m3/min

637

810

810

688

696

696

696

Mod. Normale/ Sil.

Modalità Normale

AxLxP

Lato liquido

Lato gas

Bilanciamento

dB(A)

dB(A)

mm / kg

Poll. (mm)

Poll. (mm)

Poll (mm)

63,5 / 60,5

84,5

1842 x 2780

x1000/690

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

17,80 / 37,1664

50 ~ 130 (200)

-10~+52

-25~+18

62,5 / 59,5

83,5

1842 x 3140

x1000/750

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

19,00 / 39,672

50 ~ 130 (200)

-10~+52

-25~+18

63,0 / 60,0

84,0

1842 x 3140

x1000/750

x1000/840

65,0 / 62,0

86,0

65,5 / 62,5

86,5

1842 x 3660

x1000/900

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50 ~ 130 (200)

-10~+52

-25~+18

65,5 / 62,5

86,5

1842 x 3660

x1000/945

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50 ~ 130 (200)

-10~+52

-25~+18

66,0 / 63,0

87,0

1842 x 3660

x1000/945

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50 ~ 130 (200)

-10~+52

-25~+18

1842 x 3250

Refrigerante (R410A) / CO

2

Eq

Rapporto di capacità unità interna / esterna (min / max)

4)

Gamma temp.

Raffresc. Min ~ Max °C

esterne operative

Riscald. Min ~ Max °C

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

19,00 / 39,672

50 ~ 130 (200)

-10~+52

-25~+18

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

22,20 / 46,3536

50 ~ 130 (200)

-10~+52

-25~+18

kg / T

122

1) EER e COP calcolati in base alla normativa EN14511. 2) SEER / SCOP sono calcolati in base ai valori di efficienza stagionale di raffrescamento/riscaldamento degli ambienti "η" del REGOLAMENTO (UE) 2016/2281

DELLA COMMISSIONE. SEER, SCOP = (η + Correzione) × PEF. 3) Diametro delle tubazioni inferiore a 90 m per l'unità interna finale / superiore a 90 m per l'unità interna finale (se la lunghezza equivalente della

tubazione più lunga supera i 90 m, aumentare le dimensioni dei tubi principali di 1 grado per i tubi del gas e i tubi del liquido). 4) Se sono soddisfatte le seguenti condizioni, la portata effettiva

è superiore al 130%

e inferiore al 200%: A. Rispettare il numero limitato di unit

à interne collegabili. B. Il limite inferiore di operatività con temperatura esterna di riscaldamento è limitato a -10 °C WB (standard -25 °C WB). C. Il

funzionamento simultaneo è limitato a meno del 130% delle unità interne collegabili.