Unità esterne
U-10ME2E8
U-12ME2E8
U-10ME2E8
U-12ME2E8
U-14ME2E8
U-16ME2E8
U-14ME2E8
U-12ME2E8
U-12ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-20ME2E8
Voltaggio
Alimentazione
Fase
Frequenza
22 HP
24 HP
26 HP
28 HP
30 HP
32 HP
34 HP
V
380-400-415 380-400-415 380-400-415 380-400-415 380-400-415 380-400-415 380-400-415
Trifase
Trifase
Trifase
Trifase
Trifase
Trifase
Trifase
H
z
5
0
5
0
5
0
5
0
5
0
5
0
50
A
2,00
2,00
3,00
3,00
4,00
4,00
4,00
P
a
8
0
8
0
8
0
8
0
8
0
8
0
80
m3/min
456
464
456
464
464
464
637
Capacità raffrescam.
kW
61,5
68,0
73,0
78,5
85,0
90,0
96,0
Coefficiente EER
1)
W/W
4,13
3,93
3,80
3,69
3,68
3,52
3,56
Coefficiente SEER
2)
6,90
6,86
6,62
6,60
6,88
6,55
7,21
Assorbimento
A
24,30-23,10-22,30
28,00-26,60-25,60
31,70-30,10-29,00
34,80-33,10-31,90
38,60-36,60-35,30
42,30-40,20-38,70
44,10-41,90-40,40
Consumo in raffresc.
kW
14,90
17,30
19,20
21,30
23,10
25,60
27,00
Capacità in riscald.
kW
69,0
76,5
81,5
87,5
95,0
100,0
108,0
Coefficiente COP
1)
W/W
4,76
4,69
4,55
4,56
4,48
4,42
4,17
Coefficiente SCOP
2)
4,53
4,78
4,16
4,29
4,13
4,09
4,14
Assorbimento
A
23,90-22,70-21,90
26,60-25,30-24,40
29,90-28,40-27,40
31,70-30,10-29,00
35,40-33,60-32,40
37,70-35,80-34,60
42,80-40,60-39,20
Consumo in riscald.
kW
14,50
16,30
17,90
19,20
21,20
22,60
25,90
Corrente di spunto
Pressione statica esterna (Max)
Portata d'aria
Liv. pressione sonora
Liv. potenza sonora
Dimensioni /
Peso netto
Tubi di
collegamento
3)
Mod. Normale/ Sil.
Modalità Normale
AxLxP
Lato liquido
Lato gas
Bilanciamento
dB(A)
dB(A)
mm / kg
Poll. (mm)
Poll. (mm)
Poll (mm)
61,0 / 58,0
82,0
1842 x 2010
x1000/480
5/8 (15,88) /
3/4 (19,05)
1-1/8 (28,58) /
1-1/4 (31,75)
1/4 (6,35)
13,90 / 23,3856
50 ~ 130 (200)
-10~+52
-25~+18
36 HP
380-400-415
Trifase
62,0 / 59,0
83,0
1842 x 2420
x1000/540
5/8 (15,88) /
3/4 (19,05)
1-1/8 (28,58) /
1-1/4 (31,75)
1/4 (6,35)
16,60 / 34,6608
50 ~ 130 (200)
-10~+52
-25~+18
38 HP
380-400-415
Trifase
62,5 / 59,5
83,5
1842 x 2010
x1000/525
x1000/585
63,5 / 60,5
84,5
63,5 / 60,5
84,5
1842 x 2420
x1000/630
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
16,60 / 34,6608
50 ~ 130 (200)
-10~+52
-25~+18
44 HP
380-400-415
Trifase
64,0 / 61,0
85,0
1842 x 2420
x1000/630
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
16,60 / 34,6608
50 ~ 130 (200)
-10~+52
-25~+18
46 HP
380-400-415
Trifase
63,0 / 60,0
84,0
1842 x 2780
x1000/690
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
17,80 / 37,1664
50 ~ 130 (200)
-10~+52
-25~+18
48 HP
380-400-415
Trifase
1842 x 2420
Refrigerante (R410A) / CO
2
Eq
Rapporto di capacità unità interna / esterna (min /
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
13,90 / 29,0232
50 ~ 130 (200)
-10~+52
-25~+18
40 HP
380-400-415
Trifase
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
16,60 / 34,6608
50 ~ 130 (200)
-10~+52
-25~+18
42 HP
380-400-415
Trifase
kg / T
max)
4)
Gamma temp.
esterne operative
Alimentazione
Raffresc. Min ~ Max
Riscald. Min ~ Max
Voltaggio
Fase
Frequenza
°C
°C
V
Hz
A
Pa
Unità esterne
U-16ME2E8
U-18ME2E8
U-20ME2E8
U-10ME2E8
U-12ME2E8
U-14ME2E8
U-16ME2E8
U-20ME2E8
U-20ME2E8
U-20ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
Capacità raffrescam.
kW
101,0
107,0
113,0
118,0
124,0
130,0
135,0
Coefficiente EER
1)
W/W
3,42
3,42
3,34
3,69
3,62
3,62
3,52
Coefficiente SEER
2)
6,86
7,32
7,16
6,57
6,60
6,70
6,55
Assorbimento
A
47,70-45,30-43,70
50,60-48,10-46,30
54,10-51,40-49,50
52,80-50,20-48,40
56,00-53,20-51,30
59,90-56,90-54,90
63,40-60,20-58,10
Consumo in raffresc.
kW
25,9
31,3
33,8
32,0
34,3
35,9
38,4
Capacità in riscald.
kW
113,0
119,0
127,0
132,0
138,0
145,0
150,0
Coefficiente COP
1)
W/W
4,14
4,13
3,92
4,49
4,50
4,46
4,42
Coefficiente SCOP
2)
4,06
4,14
4,13
4,11
4,21
4,12
4,09
Assorbimento
A
44,60-42,40-40,80
47,10-44,70-43,10
52,40-49,80-48,00
49,10-46,60-44,90
50,70-48,20-46,40
54,30-51,50-49,7
56,60-53,80-51,8
Consumo in riscald.
kW
27,30
28,80
32,40
29,40
30,70
32,50
33,90
Corrente di spunto
50
50
50
50
50
50
50
4,00
4,00
4,00
5,00
5,00
6,00
6,00
80
80
80
80
80
80
80
Pressione statica esterna (Max)
Portata d'aria
Liv. pressione sonora
Liv. potenza sonora
Dimensioni /
Peso netto
Tubi di
collegamento
3)
m3/min
637
810
810
688
696
696
696
Mod. Normale/ Sil.
Modalità Normale
AxLxP
Lato liquido
Lato gas
Bilanciamento
dB(A)
dB(A)
mm / kg
Poll. (mm)
Poll. (mm)
Poll (mm)
63,5 / 60,5
84,5
1842 x 2780
x1000/690
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
17,80 / 37,1664
50 ~ 130 (200)
-10~+52
-25~+18
62,5 / 59,5
83,5
1842 x 3140
x1000/750
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
19,00 / 39,672
50 ~ 130 (200)
-10~+52
-25~+18
63,0 / 60,0
84,0
1842 x 3140
x1000/750
x1000/840
65,0 / 62,0
86,0
65,5 / 62,5
86,5
1842 x 3660
x1000/900
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50 ~ 130 (200)
-10~+52
-25~+18
65,5 / 62,5
86,5
1842 x 3660
x1000/945
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50 ~ 130 (200)
-10~+52
-25~+18
66,0 / 63,0
87,0
1842 x 3660
x1000/945
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50 ~ 130 (200)
-10~+52
-25~+18
1842 x 3250
Refrigerante (R410A) / CO
2
Eq
Rapporto di capacità unità interna / esterna (min / max)
4)
Gamma temp.
Raffresc. Min ~ Max °C
esterne operative
Riscald. Min ~ Max °C
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
19,00 / 39,672
50 ~ 130 (200)
-10~+52
-25~+18
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
22,20 / 46,3536
50 ~ 130 (200)
-10~+52
-25~+18
kg / T
122
1) EER e COP calcolati in base alla normativa EN14511. 2) SEER / SCOP sono calcolati in base ai valori di efficienza stagionale di raffrescamento/riscaldamento degli ambienti "η" del REGOLAMENTO (UE) 2016/2281
DELLA COMMISSIONE. SEER, SCOP = (η + Correzione) × PEF. 3) Diametro delle tubazioni inferiore a 90 m per l'unità interna finale / superiore a 90 m per l'unità interna finale (se la lunghezza equivalente della
tubazione più lunga supera i 90 m, aumentare le dimensioni dei tubi principali di 1 grado per i tubi del gas e i tubi del liquido). 4) Se sono soddisfatte le seguenti condizioni, la portata effettiva
è superiore al 130%
e inferiore al 200%: A. Rispettare il numero limitato di unit
à interne collegabili. B. Il limite inferiore di operatività con temperatura esterna di riscaldamento è limitato a -10 °C WB (standard -25 °C WB). C. Il
funzionamento simultaneo è limitato a meno del 130% delle unità interne collegabili.