LINEA WR2 / PQH(R)Y-P Y(S)LM-A1

Specifiche tecniche WR2

MODELLO

HP

Moduli

Giunto di accoppiamento

Alimentazione

Raffreddamento

Riscaldamento

Pressione sonora

*3

Unità int. collegabili

Ø est. attacchi refr.

Acqua circolante

Dimensioni esterne (AxLxP)

Peso netto

Carica refr. R410A*

4

/CO

2

Eq

DOUBLE

V/Hz/n°

kW

kW

PQRY-P400YSLM-A1

PQRY-P450YSLM-A1

PQRY-P500YSLM-A1

PQRY-P550YSLM-A1

PQRY-P600YSLM-A1

16

18

20

22

24

Specifiche tecniche WR2

m3/h

kPa

l

mm

kg

kg/Tons

DOUBLE

V/Hz/n°

kW

kW

5,76 + 5,76

3+3 ~ 7,2+7,2

24 + 24

5,0 + 5,0

1100 x 880 x 550

1100 x 880 x 550

172+172

5,0+5,0 /20,88

PQRY-P700YSLM-A1

5,76 + 5,76

3+3 ~ 7,2+7,2

24 + 24

5,0 + 5,0

1100 x 880 x 550

1100 x 880 x 550

172+172

5,0+5,0 /20,88

PQRY-P750YSLM-A1

5,76 + 5,76

3+3 ~ 7,2+7,2

24 + 24

5,0 + 5,0

1100 x 880 x 550

1100 x 880 x 550

172+172

5,0+5,0 /20,88

PQRY-P800YSLM-A1

5,76 + 5,76

3+3 ~ 7,2+7,2

24 + 24

5,0 + 5,0

1100 x 880 x 550

1100 x 880 x 550

172+172

5,0+5,0 /20,88

PQRY-P850YSLM-A1

5,76 + 5,76

3+3 ~ 7,2+7,2

24 + 24

5,0 + 5,0

1100 x 880 x 550

1100 x 880 x 550

172+172

5,0+5,0 /20,88

PQRY-P900YSLM-A1

MODELLO

HP

Moduli

Giunto di accoppiamento

Alimentazione

Raffreddamento

Riscaldamento

Pressione sonora*

3

Unità int. collegabili

Ø est. attacchi refr.

Acqua circolante

Dimensioni esterne (AxLxP)

Peso netto

Carica refr. R410A*

4

/CO

2

Eq

28

30

32

34

36

Tensione/Freq./Fasi

Capacità

*1

Potenza assorbita

EER

PQRY-P200YLM-A

PQRY-P250YLM-A

PQRY-P250YLM-A

PQRY-P200YLM-A

PQRY-P200YLM-A

PQRY-P250YLM-A

CMY-Q100VBK

3 fasi 380-400-415V 50Hz

45,0

50,0

56,0

7,70

8,78

10,12

5,84

5,69

5,53

PQRY-P300YLM-A

PQRY-P250YLM-A

63,0

11,55

5,45

PQRY-P300YLM-A

PQRY-P300YLM-A

69,0

12,84

5,37

SEER

-

-

-

-

-

Campo operativo

di temperatura

Interna BU

Acqua in circolo

°C

°C

kW

kW

15,0~24,0

15,0~24,0

10,0~45,0

10,0~45,0

50,0

56,0

7,94

8,97

6,29

6,24

15,0~24,0

10,0~45,0

63,0

10,16

6,20

15,0~24,0

10,0~45,0

69,0

11,31

6,10

15,0~24,0

10,0~45,0

76,5

12,75

6,00

Capacità massima*

2

Potenza assorbita

COP

SCOP

-

-

-

-

-

Campo operativo

di temperatura

Modalità normale

Modello/Quantità

Liquido/Gas

Portata nominale

Range operativo portata

Calo di pressione

Volume dello scambiatore

15,0~27,0

10,0~45,0

50

50~150% della capacità

dell’unità esterna

15,0~27,0

10,0~45,0

51

50~150% della capacità

dell’unità esterna

15,0~27,0

10,0~45,0

55

50~150% della capacità

dell’unità esterna

15,0~27,0

10,0~45,0

57

50~150% della capacità

dell’unità esterna

Tensione/Freq./Fasi

Capacità*

1

Potenza assorbita

EER

PQRY-P350YLM-A

PQRY-P350YLM-A

80,0

14,73

5,43

PQRY-P400YLM-A

PQRY-P350YLM-A

85,0

15,64

5,43

PQRY-P400YLM-A

PQRY-P400YLM-A

CMY-Q100VBK

3 fasi 380-400-415V 50Hz

90,0

16,57

5,43

PQRY-P450YLM-A

PQRY-P400YLM-A

96,0

18,03

5,32

PQRY-P450YLM-A

PQRY-P450YLM-A

101,0

19,38

5,21

Interna BS

Acqua in circolo

°C

15,0~27,0

°C

10,0~45,0

dB(A)

49

50~150% della capacità

dell’unità esterna

P15~P250/1~40

mm

22,2/28,58

22,2/28,58

22,2/28,58

22,2/28,58

22,2/34,93

SEER

-

-

-

-

-

Campo operativo

di temperatura

15,0~24,0

10,0~45,0

88

14,73

5,97

15,0~24,0

10,0~45,0

95,0

15,90

5,97

15,0~24,0

10,0~45,0

100,0

16,75

5,97

15,0~24,0

10,0~45,0

108,0

18,49

5,84

15,0~24,0

10,0~45,0

113,0

19,74

5,72

Interna BU

Acqua in circolo

°C

°C

kW

kW

°C

15,0~27,0

°C

10,0~45,0

dB(A)

55

50~150% della capacità

dell’unità esterna

P15~P250/2~50

mm

28,58/34,93

28,58/34,93

28,58/34,93

28,58/41,28

28,58/41,28

Capacità massima*

2

Potenza assorbita

COP

SCOP

-

-

-

-

-

Campo operativo

di temperatura

Modalità normale

Modello/Quantità

Liquido/Gas

Portata nominale

Range operativo portata

Calo di pressione

Volume dello scambiatore

Interna BS

Acqua in circolo

15,0~27,0

10,0~45,0

55

50~150% della capacità

dell’unità esterna

15,0~27,0

10,0~45,0

55

50~150% della capacità

dell’unità esterna

15,0~27,0

10,0~45,0

56

50~150% della capacità

dell’unità esterna

15,0~27,0

10,0~45,0

57

50~150% della capacità

dell’unità esterna

*

1

Condizioni di raffreddamento nominali: interno 27°C BS / 19°C BU. Temperatura acqua 30°C Lunghezza tubazioni 7.5m, dislivello 0m.

*

2

Condizioni di riscaldamento nominali: interno 20°C BS. Temperatura acqua 20°C Lunghezza tubazioni 7.5m, dislivello 0m.

*

3

Valori misurati in camera anecoica.

*

4

GWP di HFC R410A pari a 2088 secondo regolamento 517 / 2014

I dati di SEER e SCOP sono basati in conformità allo standard di misura EN14825

72

m3/h

kPa

l

mm

kg

kg/Tons

7,20 + 7,20

4,5+4,5 ~ 11,6+11,6

44 + 44

5,0 + 5,0

1450 x 880 x 550

1450 x 880 x 550

216 + 216

6,0+6,0 /25,06

7,20 + 7,20

4,5+4,5 ~ 11,6+11,6

44 + 44

5,0 + 5,0

1450 x 880 x 550

1450 x 880 x 550

216 +216

6,0 + 6,0 /25,06

7,20 + 7,20

4,5+4,5 ~ 11,6+11,6

44 + 44

5,0 + 5,0

1450 x 880 x 550

1450 x 880 x 550

216 + 216

6,0 + 6,0 /25,06

7,20 + 7,20

4,5+4,5 ~ 11,6+11,6

44 + 44

5,0 + 5,0

1450 x 880 x 550

1450 x 880 x 550

216 +216

6,0 + 6,0 /25,06

7,20 + 7,20

4,5+4,5 ~ 11,6+11,6

44 + 44

5,0 + 5,0

1450 x 880 x 550

1450 x 880 x 550

216 + 216

6,0 + 6,0 /25,06

P15~P250/1~45

P15~P250/1~50

P15~P250/1~50

P15~P250/2~50

P15~P250/2~50

P15~P250/2~50

P15~P250/2~50

P15~P250/2~50