LINEA WR2 / PQH(R)Y-P Y(S)LM-A1
MODELLO
HP
Moduli
Giunto di accoppiamento
Alimentazione
Raffreddamento
Riscaldamento
Pressione sonora
*3
Unità int. collegabili
Ø est. attacchi refr.
Acqua circolante
Dimensioni esterne (AxLxP)
Peso netto
Carica refr. R410A*
4
/CO
2
Eq
DOUBLE
V/Hz/n°
kW
kW
PQRY-P400YSLM-A1
PQRY-P450YSLM-A1
PQRY-P500YSLM-A1
PQRY-P550YSLM-A1
PQRY-P600YSLM-A1
16
18
20
22
24
m3/h
kPa
l
mm
kg
kg/Tons
DOUBLE
V/Hz/n°
kW
kW
5,76 + 5,76
3+3 ~ 7,2+7,2
24 + 24
5,0 + 5,0
1100 x 880 x 550
1100 x 880 x 550
172+172
5,0+5,0 /20,88
PQRY-P700YSLM-A1
5,76 + 5,76
3+3 ~ 7,2+7,2
24 + 24
5,0 + 5,0
1100 x 880 x 550
1100 x 880 x 550
172+172
5,0+5,0 /20,88
PQRY-P750YSLM-A1
5,76 + 5,76
3+3 ~ 7,2+7,2
24 + 24
5,0 + 5,0
1100 x 880 x 550
1100 x 880 x 550
172+172
5,0+5,0 /20,88
PQRY-P800YSLM-A1
5,76 + 5,76
3+3 ~ 7,2+7,2
24 + 24
5,0 + 5,0
1100 x 880 x 550
1100 x 880 x 550
172+172
5,0+5,0 /20,88
PQRY-P850YSLM-A1
5,76 + 5,76
3+3 ~ 7,2+7,2
24 + 24
5,0 + 5,0
1100 x 880 x 550
1100 x 880 x 550
172+172
5,0+5,0 /20,88
PQRY-P900YSLM-A1
MODELLO
HP
Moduli
Giunto di accoppiamento
Alimentazione
Raffreddamento
Riscaldamento
Pressione sonora*
3
Unità int. collegabili
Ø est. attacchi refr.
Acqua circolante
Dimensioni esterne (AxLxP)
Peso netto
Carica refr. R410A*
4
/CO
2
Eq
28
30
32
34
36
Tensione/Freq./Fasi
Capacità
*1
Potenza assorbita
EER
PQRY-P200YLM-A
PQRY-P250YLM-A
PQRY-P250YLM-A
PQRY-P200YLM-A
PQRY-P200YLM-A
PQRY-P250YLM-A
CMY-Q100VBK
3 fasi 380-400-415V 50Hz
45,0
50,0
56,0
7,70
8,78
10,12
5,84
5,69
5,53
PQRY-P300YLM-A
PQRY-P250YLM-A
63,0
11,55
5,45
PQRY-P300YLM-A
PQRY-P300YLM-A
69,0
12,84
5,37
SEER
-
-
-
-
-
Campo operativo
di temperatura
Interna BU
Acqua in circolo
°C
°C
kW
kW
15,0~24,0
15,0~24,0
10,0~45,0
10,0~45,0
50,0
56,0
7,94
8,97
6,29
6,24
15,0~24,0
10,0~45,0
63,0
10,16
6,20
15,0~24,0
10,0~45,0
69,0
11,31
6,10
15,0~24,0
10,0~45,0
76,5
12,75
6,00
Capacità massima*
2
Potenza assorbita
COP
SCOP
-
-
-
-
-
Campo operativo
di temperatura
Modalità normale
Modello/Quantità
Liquido/Gas
Portata nominale
Range operativo portata
Calo di pressione
Volume dello scambiatore
15,0~27,0
10,0~45,0
50
50~150% della capacità
dell’unità esterna
15,0~27,0
10,0~45,0
51
50~150% della capacità
dell’unità esterna
15,0~27,0
10,0~45,0
55
50~150% della capacità
dell’unità esterna
15,0~27,0
10,0~45,0
57
50~150% della capacità
dell’unità esterna
Tensione/Freq./Fasi
Capacità*
1
Potenza assorbita
EER
PQRY-P350YLM-A
PQRY-P350YLM-A
80,0
14,73
5,43
PQRY-P400YLM-A
PQRY-P350YLM-A
85,0
15,64
5,43
PQRY-P400YLM-A
PQRY-P400YLM-A
CMY-Q100VBK
3 fasi 380-400-415V 50Hz
90,0
16,57
5,43
PQRY-P450YLM-A
PQRY-P400YLM-A
96,0
18,03
5,32
PQRY-P450YLM-A
PQRY-P450YLM-A
101,0
19,38
5,21
Interna BS
Acqua in circolo
°C
15,0~27,0
°C
10,0~45,0
dB(A)
49
50~150% della capacità
dell’unità esterna
P15~P250/1~40
mm
22,2/28,58
22,2/28,58
22,2/28,58
22,2/28,58
22,2/34,93
SEER
-
-
-
-
-
Campo operativo
di temperatura
15,0~24,0
10,0~45,0
88
14,73
5,97
15,0~24,0
10,0~45,0
95,0
15,90
5,97
15,0~24,0
10,0~45,0
100,0
16,75
5,97
15,0~24,0
10,0~45,0
108,0
18,49
5,84
15,0~24,0
10,0~45,0
113,0
19,74
5,72
Interna BU
Acqua in circolo
°C
°C
kW
kW
°C
15,0~27,0
°C
10,0~45,0
dB(A)
55
50~150% della capacità
dell’unità esterna
P15~P250/2~50
mm
28,58/34,93
28,58/34,93
28,58/34,93
28,58/41,28
28,58/41,28
Capacità massima*
2
Potenza assorbita
COP
SCOP
-
-
-
-
-
Campo operativo
di temperatura
Modalità normale
Modello/Quantità
Liquido/Gas
Portata nominale
Range operativo portata
Calo di pressione
Volume dello scambiatore
Interna BS
Acqua in circolo
15,0~27,0
10,0~45,0
55
50~150% della capacità
dell’unità esterna
15,0~27,0
10,0~45,0
55
50~150% della capacità
dell’unità esterna
15,0~27,0
10,0~45,0
56
50~150% della capacità
dell’unità esterna
15,0~27,0
10,0~45,0
57
50~150% della capacità
dell’unità esterna
*
1
Condizioni di raffreddamento nominali: interno 27°C BS / 19°C BU. Temperatura acqua 30°C Lunghezza tubazioni 7.5m, dislivello 0m.
*
2
Condizioni di riscaldamento nominali: interno 20°C BS. Temperatura acqua 20°C Lunghezza tubazioni 7.5m, dislivello 0m.
*
3
Valori misurati in camera anecoica.
*
4
GWP di HFC R410A pari a 2088 secondo regolamento 517 / 2014
I dati di SEER e SCOP sono basati in conformità allo standard di misura EN14825
72
m3/h
kPa
l
mm
kg
kg/Tons
7,20 + 7,20
4,5+4,5 ~ 11,6+11,6
44 + 44
5,0 + 5,0
1450 x 880 x 550
1450 x 880 x 550
216 + 216
6,0+6,0 /25,06
7,20 + 7,20
4,5+4,5 ~ 11,6+11,6
44 + 44
5,0 + 5,0
1450 x 880 x 550
1450 x 880 x 550
216 +216
6,0 + 6,0 /25,06
7,20 + 7,20
4,5+4,5 ~ 11,6+11,6
44 + 44
5,0 + 5,0
1450 x 880 x 550
1450 x 880 x 550
216 + 216
6,0 + 6,0 /25,06
7,20 + 7,20
4,5+4,5 ~ 11,6+11,6
44 + 44
5,0 + 5,0
1450 x 880 x 550
1450 x 880 x 550
216 +216
6,0 + 6,0 /25,06
7,20 + 7,20
4,5+4,5 ~ 11,6+11,6
44 + 44
5,0 + 5,0
1450 x 880 x 550
1450 x 880 x 550
216 + 216
6,0 + 6,0 /25,06
P15~P250/1~45
P15~P250/1~50
P15~P250/1~50
P15~P250/2~50
P15~P250/2~50
P15~P250/2~50
P15~P250/2~50
P15~P250/2~50