SERIE POWER - CERTIFICAzIONI SERIE POWER

39

certificazioni serie power

tr 20

tr 25

Manufacturer's Declaration for hot water boilers TR with

manual fuel supply (wood split logs)

Manufacturer

:

Products :

Type designation:

for the submission of official institutions

WVterm d.o.o.

Preradovičeva 22, 2000 Maribor, Slovenija

Hot-water boilers for wood with manual fuel supply

TR 20

The Engineering Test Institute, Public Enterprise, hereby certifies that the charactericstics of the

samples of the products concerned have been found conforming to the applicable requirements of

EN 303-5:2013.

The present Certificate has been issued on the basis of Final Report 31-9651/T of 2015-10-14,

issued by the Engineering Test Institute, Public Enterprise (SZU).

Nominal power (kW):

20

Efficiency (%):

92,7

Minimum power (kW):

10

Efficiency (%):

93

Converted values O

2

=13%

CO [mg/m3]

NOx [mg/m3]

THC [mg/ m3]

Dust [mg/ m3]

30

121

4

4

CO [mg/ m3]

NOx [mg/ m3]

THC [mg/ m3]

Dust [mg/ m3]

136

96

9

4

Converted values O

2

=13%

Hot-water boiler meets at nominal and minimum power output, the emission requirmements for Class 5.

Date

Signature

Company stamp

02.10.2015

Manufacturer's Declaration for hot water boilers TR with

manual fuel supply (wood split logs)

Manufacturer

:

Products :

Type designation:

for the submission of official institutions

WVterm d.o.o.

Preradovičeva 22, 2000 Maribor, Slovenija

Hot-water boilers for wood with manual fuel supply

TR 25

The Engineering Test Institute, Public Enterprise, hereby certifies that the charactericstics of the

samples of the products concerned have been found conforming to the applicable requirements of

EN 303-5:2013.

The present Certificate has been issued on the basis of Final Report 31-9651/T of 2015-10-14,

issued by the Engineering Test Institute, Public Enterprise (SZU).

Nominal power (kW):

25

Efficiency (%):

92,5

Minimum power (kW):

12,5

Efficiency (%):

93,5

Converted values O

2

=0%

CO [mg/ m3]

NOx [mg/ m3]

THC [mg/ m3]

Dust [mg/ m3]

31

129

4

4

CO [mg/ m3]

NOx [mg/ m3]

THC [mg/ m3]

Dust [mg/ m3]

94

147

8

3

Converted values O

2

=0%

Hot-water boiler meets at nominal and minimum power output, the emission requirmements for Class 5.

Date

Signature

Company stamp

02.10.2015

tr 30

Manufacturer's Declaration for hot water boilers TR with

manual fuel supply (wood split logs)

Manufacturer

:

Products :

Type designation:

for the submission of official institutions

WVterm d.o.o.

Preradovičeva 22, 2000 Maribor, Slovenija

Hot-water boilers for wood with manual fuel supply

TR 30

The Engineering Test Institute, Public Enterprise, hereby certifies that the charactericstics of the

samples of the products concerned have been found conforming to the applicable requirements of

EN 303-5:2013.

The present Certificate has been issued on the basis of Final Report 31-9651/T of 2015-10-14,

issued by the Engineering Test Institute, Public Enterprise (SZU).

Nominal power (kW):

30

Efficiency (%):

92,2

Minimum power (kW):

15

Efficiency (%):

94

Converted values O

2

=13%

CO [mg/ m3]

NOx [mg/ m3]

THC [mg/ m3]

Dust [mg/ m3]

32

137

4

4

CO [mg/ m3]

NOx [mg/ m3]

THC [mg/ m3]

Dust [mg/ m3]

58

199

6

2

Converted values O

2

=13%

Hot-water boiler meets at nominal and minimum power output, the emission requirmements for Class 5.

Date

Signature

Company stamp

02.10.2015