Description of function

Thermax DN 20 (3⁄4")

Installation beside the boiler:

Thermax is directly mounted to the wall without distance pieces

Installation below the boiler:

The pipes are installed between the Thermax (with distance pieces)

and the wall

The Thermax system has been designed for applications with two different temperature levels. An application example: it can be connected to a consumer with a

high flow temperature (such as a radiator) and a consumer with a low flow temperature (such as a radiant

floor heating).

The Thermax distribution manifold is equipped with an integrated, adjustable bypass. This bypass can be closed (distribution manifold is pressure tight - for

applications with boilers without internal pump) or it can be opened (in this case a low-loss bypass is activated in the Thermax distribution manifold - for

applications with an internal pump).

Bypass closed

Bypass open

Dimensions

01/2020 • Printed in Germany