The heating circuits recommended for combination with the system separations (36533, 36553, 36573) are listed on this page. Equipment and prices of the
heating circuits can be found on pages 101 (K31), 103 (K32) and 109 (K34).
Note: the heating circuits have to be ordered seperately. The assembly must be carried out on-site!
Application 1:
Extension of already existing heating circuits / installations with a temperature control on the primary side (mixed heating circuit with controlled flow
temperature or modulating boiler with boiler circuit pump).
Mounting example
Heating circuit
Pump
EEI*
System separation
Range of performance**
36013WH6
Wilo Stratos PICO
25/1-6
≤0,2
36533
1430 l/h = 16,6 kW
36553
1660 l/h = 19,3 kW
36573
1750 l/h = 20,3 kW
36013WP6
Wilo Para 25/6-43
≤0,2
36533
1580 l/h = 18,3 kW
36553
1830 l/h = 21,2 kW
36573
1930 l/h = 22,4 kW
36013GH6
Grundfos ALPHA2.1
25-60
≤0,17
36533
1480 l/h = 17,2 kW
36553
1710 l/h = 19,9 kW
36573
1790 l/h = 20,8 kW
36013GM6
Grundfps UPM3 Auto L
25-70 PP3
≤0,2
36533
1720 l/h = 20,0 kW
36553
2020 l/h = 23,5 kW
36573
2120 l/h = 24,6 kW
Application 2:
Extension of already existing heating circuits / installations with a pump on the primary side and high flow temperatures (bypass operation in addition to the
radiator circuits or operation with solid fuel boiler and boiler circuit pump).
Mounting example
Heating circuit
Pump
EEI*
System separation
Range of performance**
36063WH6
Wilo Stratos PICO
25/1-6
≤0,2
36533
1400 l/h = 16,3 kW
36553
1610 l/h = 18,7 kW
36573
1690 l/h = 19,6 kW
36063WP6
Wilo Para 25/6-43
≤0,2
36533
1540 l/h = 17,9 kW
36553
1780 l/h = 20,7 kW
36573
1860 l/h = 21,6 kW
36063GH6
Grundfos ALPHA2.1
25-60
≤0,17
36533
1450 l/h = 16,8 kW
36553
1650 l/h = 19,2 kW
36573
1730 l/h = 20,1 kW
36063GM6
Grundfos UPM3 Auto L
25-70 PP3
≤0,2
36533
1690 l/h = 19,6 kW
36553
1950 l/h = 22,6 kW
36573
2030 l/h = 23,6 kW
Application 3:
Complete system separation with mixing valve control on the primary side. Ensures low return temperatures of the boiler and allows the operation of several
parallel heating circuits, f. ex. on a distribution manifold.
Mounting example
Heating circuit
Pump
EEI*
System separation
Range of performance**
prim. 36053MWH6
sek. 36013WH6
Wilo Stratos PICO
25/1-6
≤0,2
36533
1380 l/h = 16,0 kW
36553
1590 l/h = 18,5 kW
36573
1660 l/h = 19,3 kW
prim. 36053MWP6
sek. 36013WP6
Wilo Para 25/6-43
≤0,2
36533
1540 l/h = 17,9 kW
36553
1750 l/h = 20,3 kW
36573
1830 l/h = 21,2 kW
prim. 36053MGH6
sek. 36013GH6
Grundfos ALPHA2.1
25-60
≤0,17
36533
1440 l/h = 16,7 kW
36553
1630 l/h = 18,9 kW
36573
1710 l/h = 19,9 kW
prim. 36053MGM6
sek. 36013GM6
Grundfps UPM3 Auto L
25-70 PP3
≤0,2
36533
1670 l/h = 19,4 kW
36553
1930 l/h = 22,4 kW
36573
2000 l/h = 23,2 kW
** At a primary temperature of 60 - 50 °C, a secondary temperature of 35 - 45 °C and a secondary residual head of 1.5 m wc
Prices excl. VAT • 01/2020 • Printed in Germany • *Energy Efficiency Index
PAW GmbH & Co. KG • 31789 Hameln • Germany • Phone: +49-5151-9856-0 • Fax: +49-5151-9856-98 • info@paw.eu • www.paw.eu
187
D
N