Design data FriwaMaxi - DN 25 (1") - up to 77 l/min (as per SPF LK 1)*, Cold water inlet temperature = 10 °C
Eingestellte Warmwasser-
Temperatur
Withdrawal of hot water with
45 °C at the preset hot water
temperature
Transmission perfor-
mance
Primary flow
temperature
necessary
45 °C
77 l/min
187kW
60 °C (LK 1)*
88 l/min
214kW
70°C
60 °C
82 l/min
200 kW
70 °C (LK 2)*
Modules
without circulation
6406510
6406515 (coated heat exchanger)
with circulation
(internal)**
6406530
6406535 (coated heat exchanger)
For further information on the product see page 242
Design data FriwaMega - DN 32 (11⁄4") - up to 123 l/min (as per SPF LK 1)*, Cold water inlet temperature = 10 °C
Eingestellte Warmwasser-
Temperatur
Withdrawal of hot water with
45 °C at the preset hot water
temperature
Transmission perfor-
mance
Primary flow
temperature
necessary
45 °C
123 l/min
300 kW
60 °C (LK 1)*
130 l/min
316kW
70°C
60 °C
133 l/min
324kW
70 °C (LK 2)*
Modules
without circulation
6407510
6407515 (coated heat exchanger)
with circulation
(internal)**
6407516
6407530 (coated heat exchanger)
For further information on the product see page 244
Single-family house (up to two showers)
LK 1 = performance indicator 1
at a set hot water temperature of 45 °C
at a primary flow temperature of 60 °C
LK 2 = performance indicator 2
at a set hot water temperature of 60 °C
at a primary flow temperature of 70 °C
**Friwa modules can be equipped subsequently with internal circulation sets - see equipment
01/2020 • Printed in Germany
PAW GmbH & Co. KG • 31789 Hameln • Germany • Phone: +49-5151-9856-0 • Fax: +49-5151-9856-98 • info@paw.eu • www.paw.eu