Dimensioning Friwa

Mounting example FriwaMini

Housing unit

70 °C / 60 °C / 10 °C

70 °C / 45 °C / 10 °C***

60 °C / 50 °C / 10 °C***

Single-family house

(up to two showers)

FriwaMicro

FriwaMicro

FriwaMicro

Single-family house

(up to three showers)

FriwaMini

FriwaMini

FriwaMini

Two-family house

FriwaMidi

FriwaMidi

FriwaMidi

3

FriwaMidi

FriwaMidi

FriwaMidi

5

FriwaMidi

FriwaMidi

FriwaMidi

10

FriwaMidi

FriwaMidi

FriwaMidi

15

FriwaMaxi

FriwaMidi

FriwaMaxi

20

FriwaMaxi

FriwaMidi

FriwaMaxi

30

2x FriwaMidi

FriwaMaxi

2x FriwaMidi

50

FriwaMega

2x FriwaMidi

FriwaMega

70

2x FriwaMaxi

FriwaMega

2x FriwaMaxi

100

2x FriwaMega

2x FriwaMaxi

2x FriwaMega

***During operation, a DHW temperature below 60 °C does not accord to DVGW 551 (German association for gas and water). The compliance with water

quality standards must be observed.

70 °C / 60 °C / 10 °C flow temperature 70 °C / Hot water temperature 60 °C / Cold water temperature 10 °C

Basis of calculation is the DHW demand of max. 12 l/min and the simultaneity factor according to DIN 4708

Dimensioning Friwa

The performance of Friwa primarily depends on the temperature in the buffer tank, which delivers the energy to heat up the DHW.

The demand of hot water depends on the flow and on the number of consumers. In larger apartment buildings, a statistic distribution of withdrawals can be

detected. The following table shows a basic overview of the application range of Friwa module variants.