Technical data
Equipment
without
circulation
with
circulation
Application range
• Domestic hot water preparation operating on the principle of a
flow-type water heater
The CE-conformity of the module has been certified
according to DIN EN 60335 and
SVGW / ACS.
Application range
• in solar thermal systems in systems
• with solid fuel boilers, oil or gas boilers
• connection to a buffer tank
*For information on design data, see page 230
Operating data
Max. pressure
Maximum operating temperature
Min. flow rate
Max. flow rate as per SPF LK 1*
Transmission performance 1 as per SPF LK 1*
Kvs value
primary: 3 bars,
secondary: 10 bars
95 °C
2 l/min
28 l/min
69 kW
primary: 3.1
secondary: 2.4
Dimensions
Check valve
Circulation line
Heat exchanger
Sensors
Controllers
primary: 1 x 200 mm wc
optional
32 Plates, Type E8ASH
2 x Pt1000
1 x VFS 2-40 l/min
FC3.10
Nominal diameter
Connections
Circulation line
Width
Centre distance, prim.
Centre distance, sec.
Height
Installation length
Depth
DN 15 (1⁄2")
primary:
3⁄4" internal thread
secondary:
3⁄4" external thread,
flat-sealing
1" ext. thread
309 mm
90 mm
90 mm / 137 mm
539 mm / 320 mm
494 mm
314 mm
Materials
Valves and
fittings
Gaskets
Insulation
Heat exchanger
Brass
AFM34/EPDM
EPP
Solder: Copper
Plates + connecting pieces:
Stainless steel
Coating (optional): Based on silica
Differential pressure diagram
F
r
i
w
a
M
i
n
i
01/2020 • Printed in Germany
238