Technical data

FriwaMega

up to 123 l/min (as per SPF LK 1)*

Application range

• Domestic hot water preparation operating on the principle of a

flow-type water heater

The CE-conformity of the module has been certified

according to DIN EN 60335 and

SVGW / ACS.

Application range

• in solar thermal systems

• in systems with solid fuel boilers, oil or gas boilers

• connection to a buffer tank

• as double cascade up to 246 l/min (as per SPF LK 1)*

*For information on design data, see page 231

Operating data

Max. pressure

Maximum operating temperature

Min. flow rate

Max. flow rate as per SPF LK 1*

Transmission performance 1 as per SPF LK 1*

Kvs value

primary: 3 bars,

secondary: 10 bars

95 °C

4 l/min

123 l/min

300 kW

primary: 11.8

secondary: 10.0

Equipment

Check valve

Circulation line

Heat exchanger

Sensors

Controllers

primary: 2 x 450 mm wc

optional

2 x 60 Plates, Type B25

primary: 1 x Pt1000

secondary: 2 x Pt1000

2 x Flow meter

FC3.10

Nominal diameter

Connections

Circulation line

Width

Centre distance, prim.

Centre distance, sec.

Height

Installation length

Depth

DN 32 (11⁄4")

primary:

11⁄2" internal thread

secondary:

11⁄2" external thread

1'' ext. thread

11⁄4" ext. thread

660 mm

158 mm

158 mm

1499 mm

1205 mm

920 mm

Materials

Valves and fittings

Gaskets

Insulation

Heat exchanger

Brass

AFM34/EPDM

EPP

Solder: Copper

Plates + connecting pieces:

Stainless steel

Coating (optional): Based

on silica

Differential pressure diagram

Dimensions

Mounting example

Cascade with 2 basic modules (item no. 6407510), pipe set for cascade

(item no. 64042962) and circulation set (item no. 6404136GHxx)

F

r

i

w

a

M

e

g

a

01/2020 • Printed in Germany

244

PAW GmbH & Co. KG • 31789 Hameln • Germany • Phone: +49-5151-9856-0 • Fax: +49-5151-9856-98 • info@paw.eu • www.paw.eu