The solar controller SC3.10 is completely mounted and preset so that only
the collector field sensor and the storage tank sensor must be installed and
connected.
The graphically animated LC display gives a quick and simple overview
on the solar installation and the operating conditions. Icons facilitate
programming the controller.
The controller comprises 17 preset systems and can be used in solar
installations with up to two collector fields or up to two domestic hot water
or buffer storage tanks. It is possible to use a solar transfer station with an
external heat exchanger and a tank for potable water or a buffer tank with
two loading areas.
The third relay output and a potential-free switch output for safety extra-low
voltage allow additionally individual control and alarm functions.
Not only temperature measurement, but also heat quantity balancing based
on flow calculation is possible by means of the sensors.With demanding
requirements, a pulse sensor or PAW FlowRotor can be connected for heat
quantity balancing.
OVERVIEW CONTROLLER FUNCTIONS
SC3.10
Display
Fully graphics-capable
LC-display
Operation
4 (5) push buttons
Relay outputs
3 x 230 V,
semiconductor relay
1 x 230 V, switching relay
1 x SELV (max. 24 V),
potential-free relay
2 x PWM signal for
speed control
Inputs
4 x Pt1000
Flow rate sensors
yes
Heat quantity measurement
yes
Back-up heating
yes
Alarm output
yes
Circulation (depending on
time / temperature)
yes
Holiday (storage tank
recooling)
yes
Solid fuel boiler
yes
Reduction of stagnation
yes
Active cooling
yes
Quick tank charging
yes
Thermostat function
yes
Interval / tube collector
yes
Internal heat exchanger, pump logic
External heat exchanger, pump logic (1 x
Q00146 additionally required)
Internal heat exchanger, zone charging,
valve logic (1 x Q00146 additionally
required)
2 storage tanks, internal heat exchanger,
valve logic (1 x Q00146 additionally
required)
2 collector fields, internal heat exchanger,
pump logic (1 x Q00146 additionally
required)
Storage tank and swimming pool, stand-
alone operation of the external heat
exchanger, pump logic (2 x Q00146
additionally required)
Internal heat exchanger, pump logic,
return temperature maintenance (2 x
Q00146 additionally required)
Storage tank and swimming pool,
stand-alone operation of the external
heat exchanger, valve logic (2 x Q00146
additionally required)
01/2020 • Printed in Germany
PAW GmbH & Co. KG • 31789 Hameln • Germany • Phone: +49-5151-9856-0 • Fax: +49-5151-9856-98 • info@paw.eu • www.paw.eu