Product range SolarBloC®

Solar stations

PAW-Dimensioning

Low-Flow 10-20 l / (m

2

x h)

High-Flow 25-40 l / (m

2

x h)

12 l / (m

2

x h) = 0,2 l (m

2

x min)

30 l / (m

2

x h) = 0,5 l (m

2

x min)

SolarBloC® midi Premium

SolarBloC® maxi Premium

SolarBloC® mega

Product range SolarBloC®

The PAW SolarBloCs are used to circulate the solar fluid in the solar circuit

efficiently. Solutions in the dimensions DN 20 to DN 32, offer a broad

application range up to 175 m2 of collector surface. To obtain a maximum

flexibility during system planning, PAW focuses on the two versions Basic and

Premium for its SolarBloCs.

The SolarBloC Basic is an inexpensive entry level version with functional

features. In contrast, the SolarBloC Premium is fully equipped with additional

temperature and flow rate sensors. Individual system requirements, such as

heat quantity measurement and the operating modes high-flow and low-

flow can be realised with the suitable SolarBloC and the optionally integrated

controller.

The SolarBloCs use high-efficiency pumps, which offer an extremely broad

adjustment range. Thus, the optional controller adjusts efficiently the pump

speed to the required flow rates.

Additionally, high-efficiency pumps save more than 50% of electrical driven

energy compared to conventional asynchronous pumps. Furthermore, these

pumps meet the energy efficiency guidelines (EuP / ErP READY) of 2015.

The controller is delivered preset, mounted and prewired to guarantee an

easy adjustment to the real system.

For a safe and quick commissioning, the solar stations SolarBloC are equipped

with pressure relief valves, ball valves as well as with fill and drain valves. The

insulation complies to EnEV

Application range of the solar stations:

Depending on their operating mode, solar thermal systems are divided into

high-flow and low-flow systems.

High-flow-systems operate with 25-40 litres per m2 of collector surface and

hour which corresponds to 0.42-0.67 l / (m2 x min). Low-flow-systems operate

with 10-20 litres per m2 of collector surface and hour which corresponds to

0.17-0.33 l / (m2 x min).

The flow rate which is circulated in the system depends on the operating

mode, on the collector surface as well as on the performance of the heat

exchanger (secondary). The dimensioning of the circulation pump depends

on the flow rate and the pressure drops which occur in the heat exchanger, in

the collector and in the piping system/valves and fittings of the system.

The application ranges/collector surfaces are mentioned in the product

description. The mentioned values refer to a pressure drop of about 3.5 m wc

and the most powerful pump in the system (assumed pressure drops: 1.5 m

wc in the collector, 1.5 m wc in the pipes and 0.5 m wc in the heat exchanger).

A specific flow rate of 0.25 l / (m2 x min) is assumed for low-flow

systems, whereas 0.5 l / (m2 x min) is assumed for high-flow systems.

The values are only a first indication for the dimensioning. It is

always essential to carry out a detailed dimensioning of the system!

290

01/2020 • Printed in Germany

PAW GmbH & Co. KG • 31789 Hameln • Germany • Phone: +49-5151-9856-0 • Fax: +49-5151-9856-98 • info@paw.eu • www.paw.eu

S

o

l

a

r

B

l

o

C

®