O
u
t
p
u
t
(
A
C
)
I
n
p
u
t
(
D
C
)
ASW
ASW
ASW
ASW
ASW
ASW
3K-LT-G2 Pro 4K-LT-G2 Pro 5K-LT-G2 Pro 6K-LT-G2 Pro 8K-LT-G2 Pro 10K-LT-G2 Pro
Max. PV array power
4500 Wp STC
6000 Wp STC
7500 Wp STC
9000 Wp STC
12000 WpSTC
15000 Wp STC
Max. input voltage
1100 V
MPP voltage range / rated input voltage
150 V to 1000 V / 630 V
Min. input voltage
125 V
Initial. feed-in voltage
180 V
Max. operating input current
16 A / 16 A
20A / 16 A
Max. short circuit current
25 A / 25 A
30 A / 25 A
No. of independent MPPT inputs / strings per MPPT input
2 / A :1 ; B : 1
Rated active power
3000 W
4000 W
5000 W
6000 W
8000 W
10000 W
Rated apparent power
3000 VA
4000 VA
5000 VA
6000 VA
8000 VA
10000 VA
Max. apparent power
3300 VA
3&4
4400 VA
3&4
5500 VA
3&4
6600 VA
3&4
8800 VA
3&4
11000 VA
3&4
AC nominal voltage
• Quick & easy-to-install with basic
tools
• Quick setup and commissioning
with Solplanet apps
• Compact wall mount design
• International quality standards
• 150 % PV array oversizing for higher
yields
• IP66 rated design for outdoor use
• User friendly app interface
• Max.20 A input current, ideal for
bifacial and large area PV modules
• Wide MPP voltage range
150V-1000V
• ShadeSol shadow management
AC voltage range
160 V to 300 V
AC grid frequency / range
50 Hz / 45 Hz to 55 Hz
60 Hz / 55 Hz to 65 Hz
220 V / 380 V
230 V / 400 V
240 V / 415 V
Max. output current
4.8A
6.4 A
8.0 A
9.6 A
12.8 A
16 A
Adjustable power factor range
0.8 leading to 0.8 lagging
Feed-in phases
3 / 3-N-PE
Harmonic distortion (THD) at rated output
< 3%
Max. efficiency / European efficiency
DC Switch
Ground fault monitoring / grid monitoring
DC reverse polarity protection / AC short circuit protection
All-pole-sensitive residual-current monitoring unit
Anti-Islanding protection
Surge protection
Protection class (according to IEC 62109-1) /
overvoltage category (according to IEC 62109-1)
Dimensions (W / H / D)
Weight
Operating temperature range
Self-consumption (at night)
Topology
Cooling concept
Degree of protection (according to IEC 60529)
Climatic category (according to IEC 60721-3-4)
Max. permissible value for relative humidity (non-condensing)
Max. operating altitude
DC connection
AC connection
Mounting type
LED indicators (Status / Fault / Communication)
Communication interface
1&2
Country of Manufacture
Certificates and approvals (more available on request)
98.3 % / 97.9 %
98.6% / 98.2 %
< 15 kg
●
● / ●
● / ●
●
●
● / Type II
I / AC : III ; DC : II
503 / 435 / 183 mm
-25°C ... +60°C
< 1 W
Non-isolated
Natural Convection
IP66
4K4H
100 %
3000 m
Plug-in connector
Plug-in connector
Wall-mount bracket
●
17.3 kg
Wi-Fi / 4G / RS485 (Optional)
China
CE, EN50549, G98/99, VDE-AR-N4105, AS/NZS 4777, C10/C11, VFR 2014 & UTE C15,
IEC62109, IEC62116, IEC61727, IEC61683, IEC60068, IEC61000, NB/T 32004
F
e
a
t
u
r
e
s
G
e
n
e
r
a
l
d
a
t
a
E
f
f
i
c
i
e
n
c
y
&
P
r
o
t
e
c
t
i
o
n
● Standard features / ○ optional features / – not available
1- Zero export installations supported with 2-pin RS485 for connection to approved smart meters
2- DRED supported with RS485 communication for Australia & New Zealand
3- The overload setting is disabled as default for AS/NZS4777 grid codes
4- For European and AS/NZS4777 grid codes the max. apparent AC power is equal to the rated power
Data at nominal conditions. All information is subject to change.