Technical Datasheet

I

n

p

u

t

(

D

C

)

ASW 75K-LT

ASW 80K-LT

ASW 100K-LT

ASW 110K-LT

Max. PV array power

112500 Wp STC

120000 Wp STC

150000 Wp STC

165000 Wp STC

Max. input voltage

1100 V

MPP voltage range / rated input voltage

200 V - 1000 V / 630 V

Min. input voltage

200 V

Models:

ASW75K-LT

ASW80K-LT

ASW100K-LT

ASW110K-LT

Safe and Reliable

• TYPE II Surge Protection for

DC&AC

• IP66 rated design for outdoor use

• Fuse free design

Higher Yields

User-friendly

• ShadeSol shadow management

• 32A input current each MPPT, ideal

for bifacial and large area PV modules

• 10 MPPT ́s for flexible PV array design

for higher yields.

• Support 7*24H monitoring

• Quick setup and commissioning

with Solplanet Apps

• String-level Management

Initial. feed-in voltage

250 V

Max. operating input current

32 A

Max. short circuit current

48 A

No. of independent MPPT inputs / strings per MPPT input

8/2

8/2

10/2

10/2

O

u

t

p

u

t

(

A

C

)

Rated active power

75000 W

80000 W

100000 W

110000 W

Max. apparent power

75000 VA

1

88000 VA

1

110000 VA

1

121000 VA

1

AC nominal voltage

220 V / 380 V

230 V / 400 V

AC voltage range

312 V - 528 V

AC grid frequency / range

50 Hz / 45 Hz - 55 Hz

60 Hz / 55 Hz - 65 Hz

AC nominal output current

114.0 A

115.8 A

144.3 A

158.8 A

Max. output current

114.0 A

127.0 A

158.8 A

174.7 A

Adjustable power factor range

0.8 leading to 0.8 lagging

Feed-in phases

3 / 3-N-PE

Harmonic distortion (THD) at rated output

< 3%

Max. efficiency / European efficiency

DC switch

Ground fault monitoring / grid monitoring

DC reverse polarity protection / AC short circuit protection

AC Overcurrent Protection

DC Surge Protection

AC Surge Protection

Residual Current Monitoring Unit

Anti-islanding Protection

Protection class (according to IEC 62109-1) /

overvoltage category (according to IEC 62109-1)

Dimensions (W / H / D)

Weight

Operating temperature range

Self-consumption (at night)

Topology

Cooling concept

Degree of protection (according to IEC 60529)

Climatic category (according to IEC 60721-3-4)

Max. permissible value for relative humidity (non-condensing)

Max. operating altitude

EMC

DC Connector

AC Connector

LED indicators (Status / Fault / Communication)

Communication interface (RS485/ WiFi/ 4G/ LAN)

Modbus-Sunspec protocol

Certificates and approvals (more available on request)

98.6% / 98.4%

● / ●

Type II

Type II

I / AC: III; DC: II

984/ 640 / 330 mm

86 kg

-25°C ... +60°C

< 3 W

Non-isolated

Active cooling

IP66

4K4H

100%

4000 m

CLASS B

DC Plug-in connector

OT/DT Terminal (Max.240mm2)

●/●/○/○

CE,IEC 62109-1/2,

IEC 61727, IEC 62116, IEC61683,EN50549-1/2,VDE4105

F

e

a

t

u

r

e

s

G

e

n

e

r

a

l

d

a

t

a

E

f

f

i

c

i

e

n

c

y

&

P

r

o

t

e

c

t

i

o

n

Three Phases Inverters 75 to 110 kW

SCHEDE TECNICHE - INVERTER

ASW LT Series

Inverter trifase di stringa | SOLPLANET da 75kW a 110kW

solplanet.net

@Solplanet

● standard features

Data at nominal conditions. All information is subject to change.

Version: Feb 2023

51

○ optional