SPECIFICHE UNITÀ ESTERNE

Unità esterne VRF innovative dotate di Intelligenza Artificiale nativa (AI),

nuovo Compressore con Advance Flash Injection (AFI

TM)

e ventilatore a profilo variabile.

D.F.

DETRAZIONI

FISCALI*

C.T.

CONTO

TERMICO*

1,695mm

DVM S2 POMPA DI CALORE - COMBINAZIONE STANDARD

930mm

1,295mm

765mm

MODELLO

80 HP (8+24+24+24)

82 HP (10+24+24+24)

84 HP (12+24+24+24)

3, 4, 380-415, 50

3, 4, 380-415, 50

3, 4, 380-415, 50

Pompa di Calore

Pompa di Calore

Pompa di Calore

64

80

64

64

82

84

224.0 / 224.0

(1)

229.6 / 229.6

(1)

235.2 / 235.2

(1)

252.0 / 224.0

(1)

258.3 / 229.6

(1)

264.6 / 235.2

(1)

162.75

168.56

169.98

146.24

149.64

151.56

183.0

188.0

190.0

225

225

225

-

-

-

-

-

-

Scroll Inverter x 7

151 x 1 + 365 x 3 | -

Scroll Inverter x 7

Scroll Inverter x 7

167 x 1 + 365 x 3 | -

196 x 1 + 365 x 3 | -

22.22 (7/8)

22.22 (7/8)

22.22 (7/8)

53.98 (2-1/8)

-

53.98 (2-1/8)

53.98 (2-1/8)

-

-

200(220), 110(50)

200(220), 110(50)

200(220), 110(50)

R410A

R410A

R410A

5.5 x 1 + 14.0 x 3

70, 92

5.5 x 1 + 14.0 x 3

7.0 x 1 + 14.0 x 3

99.18

99.18

102.31

70, 92

70, 92

(930 x1,695 x 765) x1 +

(1,295 x 1,695 x 765) x 3

175 x 1 + 325 x 3

(930 x1,695 x 765) x1 +

(1,295 x 1,695 x 765) x 3

(930 x1,695 x 765) x1 +

(1,295 x 1,695 x 765) x 3

185 x 1 + 325 x 3

205 x 1 + 325 x 3

-5~50 / -25~24

-5~50 / -25~24

-5~50 / -25~24

Alimentazione

Tipologia

Numero max interne collegabili

Ф, #, V, Hz

-

-

HP

Raffr.

kW

Risc.

kW

Raffr.

Risc.

A

Capacità

Assorbimento

Efficienza

Compressori

Ventilatore

Tubazioni

frigorifere

Refrigerante

Rumorosità

Dimensionali

HP

Capacità nominale

Corrente assorbita

nominale

Massima corrente assorbita

Magnetotermico

SEER

SCOP

Tipologia

Portata d'aria | Prevalenza

Tubazione liquido

Tubazione gas

Tubazioni gas (Recupero di calore)

Limiti installativi

Lunghezza Equiv., Dislivello Max

Tipologia

Carica di fabbrica

tCO

2

e

Pressione sonora, Potenza sonora

Dimensioni nette (LxAxP)

Peso netto

A

W/W

W/W

-

m

3

/min | Pa

Ф,mm(inch)

Ф,mm(inch)

Ф,mm(inch)

m

-

kg

tCO

2

e

dB(A)

mm

Kg

°C

Ф, #, V, Hz

-

-

HP

Raffr.

kW

Risc.

kW

Raffr.

Risc.

A

Campo di funzionamento Raffr. / Risc. (min~max)

Alimentazione

Tipologia

Numero max interne collegabili

MODELLO

86 HP (14+24+24+24)

88 HP (16+24+24+24)

90 HP (18+24+24+24)

3, 4, 380-415, 50

3, 4, 380-415, 50

3, 4, 380-415, 50

Pompa di Calore

Pompa di Calore

Pompa di Calore

64

86

64

64

88

90

241.6 / 241.6

(1)

246.6 / 246.6

(1)

252.0 / 252.0

(1)

271.8 / 241.6

(1)

277.2 / 246.6

(1)

283.5 / 252.0

(1)

177.87

179.62

184.02

155.55

156.87

159.03

194.0

197.0

204.2

225

225

225

-

-

-

-

-

-

Scroll Inverter x 7

210 x 1 + 365 x 3 | -

Scroll Inverter x 7

Scroll Inverter x 7

303 x 1 + 365 x 3 | -

324 x 1 + 365 x 3 | -

22.22 (7/8)

22.22 (7/8)

22.22 (7/8)

53.98 (2-1/8)

-

53.98 (2-1/8)

53.98 (2-1/8)

-

-

200(220), 110(50)

200(220), 110(50)

200(220), 110(50)

R410A

R410A

R410A

7.0 x 1 + 14.0 x 3

71, 93

8.0 x 1 + 14.0 x 3

8.0 x 1 + 14.0 x 3

102.31

104.40

104.40

70, 92

70, 92

(930 x1,695 x 765) x1 +

(1,295 x 1,695 x 765) x 3

207 x 1 + 325 x 3

(1,295 x 1,695 x 765) x 4

(1,295 x 1,695 x 765) x 4

242 x 1 + 325 x 3

242 x 1 + 325 x 3

-5~50 / -25~24

-5~50 / -25~24

-5~50 / -25~24

Capacità

Assorbimento

Efficienza

Compressori

Ventilatore

Tubazioni

frigorifere

Refrigerante

Rumorosità

Dimensionali

HP

Capacità nominale

Corrente assorbita

nominale

Massima corrente assorbita

Magnetotermico

SEER

SCOP

Tipologia

Portata d'aria | Prevalenza

Tubazione liquido

Tubazione gas

Tubazioni gas (Recupero di calore)

Limiti installativi

Lunghezza Equiv., Dislivello Max

Tipologia

Carica di fabbrica

tCO

2

e

Pressione sonora, Potenza sonora

Dimensioni nette (LxAxP)

Peso netto

A

W/W

W/W

-

m

3

/min | Pa

Ф,mm(inch)

Ф,mm(inch)

Ф,mm(inch)

m

-

kg

tCO

2

e

dB(A)

mm

Kg

°C

Campo di funzionamento Raffr. / Risc. (min~max)

*Per le unità che beneficiano delle detrazioni fiscali o incentivi conto termico consultare il sito https://www.samsung.com/it/business/climate/environment

Condizioni di test: Capacità di raffreddamento nominale: temperatura aria interna 27°C (bulbo secco) / 19°C (bulbo umido); temperatura aria esterna 35°C (bulbo secco) / 24°C (bulbo umido).

Capacità di riscaldamento nominale: temperatura aria interna 20°C (bulbo secco) / 15°C (bulbo umido); temperatura aria esterna 7°C (bulbo secco) / 6°C (bulbo umido).

Lunghezza equivalente tubazione refrigerante: 7.5 m; Dislivello: 0 m - Valore di pressione sonora acquisito in camera anecoica. Il valore potrebbe variare in funzione delle condizioni installative.

(1)

In accordo con la normativa EN 14825 e con le condizioni di test EUROVENT.