Nominal cooling capacity (Min~Max)
Power Consumption
COP
Sound power level
Air flow
Net weight
Refrigerant piping size
Number of Connectable indoor units
Nominal cooling capacity (Min~Max)
Power Consumption
COP
Sound power level
Air flow
Net weight
Refrigerant piping size
Number of Connectable indoor units
・The data are measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27 ̊CDB, 19 ̊CWB, and outdoor temp. of 35 ̊CDB.
outdoor temp. of 7 ̊CDB, 6 ̊CWB.
6.0(1.8~7.5)
1.43(0.50~2.39)
1.45(0.60~3.00)
4.69
63
65
42.0
42.0
49.5
Min.2~Max.3
12.5(1.8~14.0)
3.90(0.65~4.80)
3.25(0.70~3.42)
4.15
69
72
75.0
82.0
6.35(1/4") ×6
9.52(3/8") ×6
Min.4*~Max.6
Heating: Indoor temp. of 20 ̊CDB, and
Item
Model
Power Source
Nominal heating capacity (Min~Max)
EER
Max. running current
Sound pressure level
Refrigerant
Outdoor operating
temperature range
EER
Max. running current
Sound pressure level
Exterior dimensions (H
Refrigerant
Outdoor operating
temperature range
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Type/GWP
Charge
Liquid
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Type/GWP
Charge
Liquid
Cooling
kW
kW
kW
kW
A
dB(A)
dB(A)
dB(A)
dB(A)
m
3
/min
kg
kg/TCO
2
Eq
Φmm
̊C
A
dB(A)
dB(A)
dB(A)
dB(A)
m
3
/min
SCM40ZS-S
4.0(1.5~5.9)
4.5(1.3~6.3)
0.84(0.59~2.13)
0.90(0.54~1.70)
4.76
5.00
14
62
64
48
50
32.5
4.49
4.30
20
63
66
50
54
50.0
For two rooms
42.0
1.9/3.967
6.35(1/4") ×2
9.52(3/8") ×2
SCM45ZS-S
1Phase, 220 - 240V, 50Hz
4.5(1.5~6.4)
5.3(1.3~6.5)
1.04(0.59~2.30)
1.15(0.54~1.92)
4.33
4.61
14
62
64
49
50
32.5
4.10
4.12
20
66
66
54
54
56.0
R410A/2088
5.0(1.8~7.1)
6.0(1.4~7.5)
1.05(0.60~2.15)
1.21(0.55~2.58)
4.76
4.96
14
61
63
48
50
41.0
3.50
4.10
29
68
71
56
59
75.0
For three rooms
SCM50ZS-S1
2.5/5.22
SCM60ZM-S1
6.8(1.5~7.8)
4.20
17
50
52
Exterior dimensions (H
Heating
mm
32.5
595×780(+90) ×290
32.5
41.0
640 ×850(+65) ×290
49.0
6.35(1/4") ×3
9.52(3/8") ×3
Gas
Cooling
-15~43
Total indoor units capacity
Power Source
Nominal heating capacity (Min~Max)
Cooling
Heating
kW
kW
kW
kW
kW
2
6.0
7.1(1.8~8.8)
8.6(1.5~9.4)
1.58(0.48~2.75)
2.00(0.60~3.35)
2
7.0
-15~24
1Phase, 220 - 240V, 50Hz
8.0(1.8~9.2)
9.3(1.5~9.8)
1.95(0.48~2.83)
2.26(0.60~3.43)
Min.2~Max.3
8.5
10.0(1.8~12.0)
12.0(1.5~13.5)
2.86(0.65~4.03)
2.93(0.70~3.40)
11.0
Item
Model
SCM71ZM-S1
For four rooms
SCM80ZM-S1
SCM100ZM-S
For five/six rooms
SCM125ZM-S
13.5(1.5~14.0)
3.21
29
57
60
mm
kg
kg/TCO
2
Eq
Φmm
̊C
56.0
750 ×880(+73) ×340
62.0
3.15/6.577
6.35(1/4") ×4
9.52(3/8") ×4
56.0
R410A/2088
-15~43
75.0
6.35(1/4") ×5
9.52(3/8") ×5
945 ×970(+73) ×370
92.0
6.0/12.528
Gas
Total indoor units capacity
Heating
kW
Min.2~Max.4
12.5
Min.2~Max.4
13.5
-15~24
Min.4*~Max.5
16.0
19.5
・Sound level Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
・‘tonne(s) of CO
2
equivalent’ means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global
warming potential.
* In case of SRK71ZR+SRK71ZR, 2 Indoor units can be connectable. In case of the combination with SRK-ZSX, SRK71ZR & FDE50VH, only 3 indoor units can be connectable.
The total connecting capacity of indoor units should be between 100 ~ 160. (SCM100ZM-S, SCM125ZM-S)