SPECIFICATIONS

Nominal cooling capacity (Min~Max)

Power Consumption

COP

Sound power level

Air flow

Net weight

Refrigerant piping size

Number of Connectable indoor units

Nominal cooling capacity (Min~Max)

Power Consumption

COP

Sound power level

Air flow

Net weight

Refrigerant piping size

Number of Connectable indoor units

6.0(1.7~7.5)

1.32(0.43~2.28)

1.40(0.32~2.80)

4.86

62

64

41.0

41.0

9.52(3/8") ×3

Min.2~Max.3

8.0(1.8~9.2)

1.70(0.48~2.83)

1.95(0.35~3.12)

4.77

66

67

56.0

56.0

Min.2~Max.4

Heating: Indoor temp. of 20 ̊CDB, and

Item

Model

Power Source

Nominal heating capacity (Min~Max)

EER

Max. running current

Sound pressure level

Exterior dimensions (H

×W×D)

Refrigerant

Outdoor operating

temperature range

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

Type/GWP

Charge

Liquid

kW

kW

kW

kW

A

dB(A)

dB(A)

dB(A)

dB(A)

m

3

/min

kg

kg/TCO

2

Eq

Φmm

SCM40ZS-W

4.0(1.5~5.9)

4.5(1.0~6.3)

0.80(0.34~2.10)

0.83(0.25~1.48)

5.00

5.42

14

62

64

49

51

32.5

For two rooms

40.0

1.4/0.945

6.35(1/4") ×2

9.52(3/8") ×2

SCM45ZS-W

1Phase, 220 - 240V, 50Hz

4.5(1.5~6.4)

5.3(1.0~6.5)

0.96(0.34~2.30)

1.06(0.25~1.48)

4.69

5.00

14

63

65

50

52

32.5

R32/675

5.0(1.7~7.1)

6.0(1.0~7.5)

1.02(0.43~2.15)

1.16(0.32~2.50)

4.90

5.17

15

62

64

49

52

41.0

For three rooms

SCM50ZS-W

1.8/1.215

SCM60ZS-W

6.8(1.0~7.8)

4.55

15

50

52

mm

32.5

595×780(+90) ×290

32.5

41.0

640 ×850(+65) ×290

48.5

6.35(1/4") ×3

Gas

Cooling

-15~46

Total indoor units capacity

Heating

̊C

2

2

-15~24

Min.2~Max.3

kW

6.0

7.0

8.5

11.0

Item

Model

For four rooms

Power Source

Nominal heating capacity (Min~Max)

EER

Max. running current

Sound pressure level

Outdoor operating

temperature range

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Charge

Liquid

kW

kW

kW

kW

A

dB(A)

dB(A)

dB(A)

dB(A)

m

3

/min

kg/TCO

2

Eq

Φmm

SCM71ZS-W

7.1(1.8~8.8)

8.6(1.1~9.4)

1.42(0.48~2.75)

1.75(0.35~3.00)

5.00

4.91

20

63

67

50

54

50.0

1Phase, 220 - 240V, 50Hz

61.0

6.35(1/4") ×4

9.52(3/8") ×4

SCM80ZS-W

9.3(1.1~9.8)

4.71

20

54

54

Exterior dimensions (H

×W×D)

R32/675

2.55/1.721

Refrigerant

Heating

Type/GWP

mm

kg

56.0

750 ×880(+73) ×340

Gas

Cooling

-15~46

Total indoor units capacity

Heating

̊C

kW

Min.2~Max.4

12.5

-15~24

13.5

・The data are measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27 ̊CDB, 19 ̊CWB, and outdoor temp. of 35 ̊CDB.

outdoor temp. of 7 ̊CDB, 6 ̊CWB.

・Sound level Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.

・‘tonne(s) of CO

2

equivalent’ means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global

warming potential.

37