Unità esterna
2MXM40N(9)
Unità interna
Capacità totale (kW)
Nom.
Max.
Min.
Corrente totale (A)
EER
Unità esterna
2MXM40N(9)
Unità interna
Capacità totale (kW)
Nom.
Max.
Min.
Corrente totale (A)
Nom.
Max.
Capacità di raff. (kW)
Locale A Locale B Min.
Potenza assorbita (kW)
Nom.
Max.
Min.
Efficienza stagionale
SEER Pdesign
1.5
1.50
---
1.30
2.0
2.00
---
1.30
2.5
2.50
---
1.30
3.5
3.50
---
1.30
1.5+1.5
1.50
1.50
1.50
1.5+2.0
1.50
2.00
1.50
1.5+2.5
1.50
2.50
1.50
1.5+3.5
1.20
2.80
1.50
2.0+2.0
2.00
2.00
1.50
2.0+2.5
1.78
2.22
1.50
2.0+3.5
1.45
2.55
1.50
2.5+2.5
2.00
2.00
1.50
2.5+3.5
1.67
2.33
1.50
1.50
2.00
0.33
2.00
2.40
0.33
2.50
3.00
0.33
3.50
4.00
0.33
3.00
3.60
0.31
3.50
4.00
0.31
4.00
4.20
0.31
4.00
4.40
0.31
4.00
4.20
0.31
4.00
4.30
0.31
4.00
4.50
0.31
4.00
4.40
0.31
4.00
4.60
0.31
0.31
0.40
1.78
0.44
0.57
1.78
0.61
0.80
1.78
1.04
1.35
1.78
0.60
0.73
1.67
0.79
0.91
1.67
0.98
1.03
1.67
0.96
1.06
1.67
0.97
1.02
1.67
0.96
1.04
1.67
0.95
1.08
1.67
0.96
1.06
1.67
0.94
1.09
1.67
1.70
2.17
---
---
---
---
---
2.38
3.09
---
---
---
---
---
3.33
4.40
---
---
---
---
---
5.71
7.38
---
---
---
---
---
Capacità di risc. (kW)
Locale A Locale B Min.
Potenza assorbita (kW)
Nom.
Max.
Min.
1.5
2.00
---
1.00
2.0
3.00
---
1.00
2.5
3.40
---
1.00
3.5
3.80
---
1.00
1.5+1.5
1.75
1.75
1.20
1.5+2.0
1.63
2.17
1.20
1.5+2.5
1.58
2.63
1.20
1.5+3.5
1.26
2.94
1.20
2.0+2.0
2.10
2.10
1.30
2.0+2.5
1.87
2.33
1.30
2.0+3.5
1.53
2.67
1.30
2.5+2.5
2.10
2.10
1.30
2.5+3.5
1.75
2.45
1.30
2.00
3.30
0.26
3.00
3.70
0.26
3.40
4.10
0.26
3.80
4.40
0.26
3.50
4.30
0.24
3.80
4.50
0.24
4.20
4.60
0.24
4.20
4.70
0.24
4.20
4.60
0.24
4.20
4.70
0.24
4.20
4.80
0.24
4.20
4.70
0.24
4.20
4.80
0.24
0.68
1.04
1.43
0.83
1.24
1.43
1.02
1.48
1.43
1.28
1.71
1.43
0.80
0.99
1.31
0.88
1.04
1.31
1.00
1.10
1.31
0.96
1.12
1.31
0.98
1.08
1.31
0.97
1.09
1.31
0.95
1.09
1.31
0.96
1.08
1.31
0.94
1.08
1.31
3.66
5.69
---
---
---
---
---
4.52
6.78
---
---
---
---
---
5.59
8.09
---
---
---
---
---
7.02
9.40
---
---
---
---
---
Condizioni della capacità di riscaldamento
Temperatura interna 20°C DB
Temperatura esterna 7°C DB / 6°C WB
Condizioni della capacità di raffrescamento
Temperatura interna 27°C DB / 19°C WB
Temperatura esterna 35°C DB
Nom.
Max.
Etichetta
CEA (kWh)
3.33
4.00
4.35
4.98
5.37
5.64
5.30
5.83
5.34
5.61
5.30
5.70
5.25
5.91
5.27
5.80
5.20
5.98
4.97
4.43
4.10
4.16
4.13
4.16
4.20
4.18
4.24
COP
A+++
8.66
3.00
122
A+++
8.60
3.50
143
A+++
8.55
4.00
164
A++
8.26
4.00
170
A+++
8.53
4.00
165
A+++
8.50
4.00
165
A++
8.19
4.00
171
A++
8.36
4.00
168
A++
8.11
4.00
173
Efficienza stagionale
Etichetta SCOP Pdesign CEA (kWh)
4.43
5.45
4.35
4.85
5.75
4.32
5.53
6.06
4.18
5.29
5.92
4.37
5.41
5.93
4.28
5.36
6.00
4.32
5.25
6.00
4.41
5.29
5.92
4.37
5.19
5.94
4.46
A++
4.62
3.00
908
A++
4.61
3.20
972
A++
4.60
3.20
972
A++
4.63
3.20
968
A++
4.64
3.20
966
A++
4.60
3.20
973
A++
4.60
3.20
974
A++
4.60
3.20
974
A++
4.61
3.20
971
5