Rev. P
SELECTION CHART
Pump type
Single phase
Three phase
Power
[kW] [HP]
Q=Capacity
l/min
0
2
0
4
0
7
0
10
0
12
0
15
0
20
0
25
0
32
0
400
m
3
/h
0 1.2
2.4
4.2
6
7.2
9
12
15
19.2
24
H=Total manometric head in meters
LPS 25/08M
LPS 25/08
0. 08
0.1
7.2
6.5
5
2.4
-
-
-
-
-
-
-
LPS 25/15M
LPS 25/15
0. 15
0.2
10 .3
9.3
7.8
4.9
-
-
-
-
-
-
-
LPS 25/25M
LPS 25/25
0. 25
0 .33
13 .7
12 .5
11 .1
8.4
-
-
-
-
-
-
-
LPS 32/25M
LPS 32/25
0. 25
0 .33
12 .0
-
10 .7
9.1
7.2
5.9
3.9
-
-
-
-
LPS 32/40M
LPS 32/40
0.4
0.5
16 .4
-
14 .5
12 .7
10 .6
9.2
7
-
-
-
-
LPS 40/25M
LPS 40/25
0. 25
0 .33
7.9
-
-
7.8
7.1
6.6
5.6
3.7
-
-
-
LPS 40/40M
LPS 40/40
0.4
0.5
11 .8
-
-
11 .3
10 .4
9.9
8.7
6.9
4.4
-
-
LPS 40/75M
LPS 40/75
0. 75
1
17 .3
-
-
16 .6
16
15 .2
14 .1
12 .3
10 .1
-
-
LPS 50/40M
LPS 50/40
0. 40
0.5
9.8
-
-
-
-
9.1
8.8
7.4
5.9
3.5
-
LPS 50/75M
LPS 50/75
0. 75
1
14 .8
-
-
-
-
13 .8
13 .3
12 .3
10 .7
8.2
5
LPS 50/150M
LPS 50/150
1.5
2
20 .7
-
-
-
-
19 .8
19 .3
18 .7
17 .8
16
13 .7