Alimentazione
Power supply
Assorbimento
Consumption
Uscita CO
CO output
Campo di misura
Measure Range
Risposta 10m tubo ( T
90
)
10 m tube
Guasto generale
General fault
Guasto pompa
Pompe fault
Flusso non corretto
Flow not correct
Dimensioni (A x L x P)
Size (H x L x W)
Peso
Weight
Temperatura di esercizio
Operation temperature
Umidità di esercizio
Operation Humidity
24 Vcc (-10 / + 15%)
24 Vcc (-10 / + 15%)
4 W Max
4 W Max
4÷20 mA lineare
4÷20 mA linear
0÷100 ppm
0÷100 ppm
≤ 2 minuti
≤ 2 minutes
Uscita CO = < 1 mA o >25 mA
CO output = < 1 mA o > 25mA
Uscita CO = < 1 mA
CO output = < 1mA
Uscita CO = < 1 mA
CO output = < 1mA
380 x 350 x 80 mm
380 x 350 x 80 mm
7 Kg
7 Kg
+ 5 °C ÷ + 45 °C
+ 5 °C ÷ + 45 °C
15 ÷ 95%
15 ÷ 95%
L’unità AN510CC è utilizzata per la misurazione e la trasmissione del valore di concentrazione di
monossido di carbonio (CO) in ambiente. L’elevatissima sensibilità del dispositivo e l’elevato grado
di affidabilità data dalla presenza di due sensori elettrochimici ridondanti tra loro, fa dello strumento
l’ideale soluzione per percepire il più piccolo principio d’incendio in modo fortemente preventivo
rispetto a sistemi più tradizionali. Il suo intervento precoce permette quindi di salvaguardare tutti beni
da proteggere perché l’allarme sarà evidente persino quando la fiamma deve ancora svilupparsi.
• Elevatissima sensibilità
• Misure di concentrazione ridondanti
• Controllo di flusso automatico
• Cartucce sensori intercambiabili
• Cartucce sensori precalibrate
• Due sonde di aspirazione comprese
• Trattamento accurato del campione da analizzare
• Deumidificazione efficace
• Finissimo filtraggio delle impurità
• Chiare indicazioni ottiche sul frontale:
- LED verde: Pompa in funzione
- LED gialli (2): Flusso aspirazione fumi non regolare
- LED rosso: Allarme per aspirazione insufficiente o mancante
The AN510CC unit measures and transmits the concentration value of carbon monoxide
(CO) in the environment; the unit is run by simply connecting it to a gas plant. The
extreme sensitivity of the device and a high degree of efficiency, ensured with the use of
two intercommunicating electrochemical sensors, make this the perfect instrument for
detecting the smallest signs of fire more quickly than any other traditional system. Its fast
response permits the protection of all equipment because the alarm is triggered even before
flames have the chance to develop. he exceptional efficiency of this product is guaranteed
by an automatic extraction flow control system, with fault alarm, that adapts extraction
automatically when there is an increase in leakage caused by impurities or wear and tear.
• Extreme sensitivity
• Redundant concentration measurements
• Automatic flow control
• Interchangeable sensor cartridges
• Pre-calibrated sensor cartridges
• Two extraction sensors included
• Precise treatment of the sample under analysis
• Efficient dehumidification
• Filtration of infinitesimal impurities
• Clear visual indications on the front:
-Green LED: Pump in operation
- Yellow LEDs (2): Irregular flow of fume extraction
- Red LED: Alarm signalling insufficient or no extraction
Temperatura immagazzinamento - 20 °C ÷ 50 °C
Weight
Umidità immagazzinamento
Storage humidity
Numero di celle installate
N°of cells installed
Risoluzione
Resolution
Deriva a lungo termine
Long term drift
Ripetibilità
Repeatability
Vita media in aria pulitae
Average time in clean air
- 20 °C ÷ 50 °C
15 ÷ 98%
15 ÷ 98%
2 elettrochimiche
2 electrochemicals
1 ppm
1 ppm
< 2% il mese
< 2 % month
1% sul segnale
1% on the signal
2 anni circa
around 2 years
49