R410A

INDICE GENERALE

Serie ECOi EX ME2 a 2 tubi, combinazione di modelli ad alta efficienza da 18 a 64 HP

HP

Unità esterna

Alimentazione

Tensione

Fase

Frequenza

V

Hz

18 HP

U-8ME2E8

U-10ME2E8

380-400-415

3ph

50

20 HP

U-10ME2E8

U-10ME2E8

380-400-415

3ph

50

2,00

80

448

59,0

56,0

80,0

1842x1600

x1000/420

5/8 (15,88) /

3/4 (19,05)

1-1/8 (28,58) /

1-1/4 (31,75)

1/4 (6,35)

11,20 / 23,3856

50~130(200)

-10~+52

-25~+18

32 HP

22 HP

U-10ME2E8

U-12ME2E8

380-400-415

3ph

50

2,00

80

456

61,0

58,0

82,0

1842x2010

x1000/480

5/8 (15,88) /

3/4 (19,05)

1-1/8 (28,58) /

1-1/4 (31,75)

1/4 (6,35)

13,90 / 29,0232

50~130(200)

-10~+52

-25~+18

34 HP

24 HP

U-12ME2E8

U-12ME2E8

380-400-415

3ph

50

2,00

80

464

62,0

59,0

83,0

1842x2420

x1000/540

5/8 (15,88) /

3/4 (19,05)

1-1/8 (28,58) /

1-1/4 (31,75)

1/4 (6,35)

16,60 / 34,6608

50~130(200)

-10~+52

-25~+18

36 HP

26 HP

U-10ME2E8

U-16ME2E8

380-400-415

3ph

50

3,00

80

456

62,5

59,5

83,5

1842x2010

x1000/535

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

13,90 / 29,0232

50~130(200)

-10~+52

-25~+18

38 HP

28 HP

U-12ME2E8

U-16ME2E8

380-400-415

3ph

50

3,00

80

464

63,5

60,5

84,5

1842x2420

x1000/585

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

16,60 / 34,6608

50~130(200)

-10~+52

-25~+18

40 HP

U-12ME2E8

U-12ME2E8

U-16ME2E8

380-400-415

3ph

50

4,00

80

696

64,5

61,5

85,5

1842 x 3660

x1000/855

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 46,3536

50~130(200)

-10~+52

-25 ~ +18

Capacità di raffresc.

kW

50,0

56,0

61,5

68,0

73,0

78,5

EER

1)

W/W

4,55

4,38

4,13

3,93

3,80

3,69

Corrente

A

18,20 - 17,30 - 16,60

21,40 - 20,30 - 19,60

24,30 - 23,10 - 22,30

28,00 - 26,60 - 25,60

31,70 - 30,10 - 29,00

34,80 - 33,10 - 31,90

Potenza d'ingresso

kW

11,00

12,80

14,90

17,30

19,20

21,30

Capacità di riscald.

kW

56,0

63,0

69,0

76,5

81,5

87,5

COP

1)

W/W

4,96

4,77

4,76

4,69

4,55

4,56

Corrente

A

18,70 - 17,70 - 17,10

22,00 - 20,90 - 20,20

23,90 - 22,70 - 21,90

26,60 - 25,30 - 24,40

29,90 - 28,40 - 27,40

31,70 - 30,10 - 29,00

Potenza d'ingresso

kW

11,30

13,20

14,50

16,30

17,90

19,20

Corrente di avviamento

Pressione statica esterna (max.)

A

2,00

Pa

80

m3/min

448

dB(A)

58,5

dB(A)

55,5

dB(A)

79,5

Portata d'aria

Pressione sonora

Potenza sonora

Dimensioni /

Peso netto

Diametro delle

tubazioni

2)

Normale

Modalità silenziosa

Modalità normale

A xL xP

Liquido

Gas

Bilanciamento

mm / kg

Pollici (mm)

Pollici (mm)

Pollici (mm)

1842x1600

x1000/420

5/8 (15,88) /

3/4 (19,05)

1-1/8 (28,58) /

1-1/4 (31,75)

1/4 (6,35)

11,20 / 23,3856

50~130(200)

-10~+52

-25~+18

30 HP

Refrigerante (R410A) / CO

2

Eq.

Rapporto di capacità interna/esterna

massimo consentito

3)

kg

%

°C

°C

V

Hz

A

Pa

/T

Campo di

funzionamento

HP

Unità esterna

Alimentazione

Raffresc. Min ~ Max

Riscald. Min ~ Max

Tensione

Fase

Frequenza

U-14ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-10ME2E8

U-12ME2E8

U-10ME2E8

U-12ME2E8

U-12ME2E8

U-12ME2E8

U-12ME2E8

U-12ME2E8

U-16ME2E8

Capacità di raffresc.

kW

85,0

90,0

96,0

101,0

107,0

113,0

EER

1)

W/W

3,68

3,52

4,05

3,95

3,84

3,75

Corrente

A

38,60 - 36,60 - 35,30

42,30 - 40,20 - 38,70

38,70 - 36,80 - 35,50

41,40 - 39,30 - 37,90

46,10 - 43,80 - 42,20

49,20 - 46,70 - 45,00

Potenza d'ingresso

kW

23,10

25,60

23,70

25,60

27,90

30,10

Capacità di riscald.

kW

95,0

100,0

108,0

113,0

119,0

127,0

COP

1)

W/W

4,48

4,42

4,72

4,73

4,61

4,57

Corrente

A

35,40 - 33,60 - 32,40

37,70 - 35,80 - 34,60

37,80 - 35,90 - 34,60

39,00 - 37,10 - 35,80

42,60 - 40,50 - 39,00

45,90 - 43,60 - 42,00

Potenza d'ingresso

kW

21,20

22,60

22,90

23,90

25,80

27,80

Corrente di avviamento

Pressione statica esterna (max.)

380-400-415

3ph

50

4,00

80

464

63,5

60,5

84,5

1842 x 2420

x1000/630

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

16,60 / 34,6608

50~130(200)

-10~+52

-25 ~ +18

380-400-415

3ph

50

4,00

80

464

64,0

61,0

85,0

1842 x 2420

x1000/630

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

16,60 / 34,6608

50~130(200)

-10~+52

-25 ~ +18

380-400-415

3ph

50

3,00

80

688

63,0

60,0

84,0

1842 x 3250

x1000/750

3/4 (19,05) /

7/8 (22,22)

1-1/4 (31,75) /

1-1/2 (38,10)

1/4 (6,35)

22,20 / 46,3536

50~130(200)

-10~+52

-25 ~ +18

380-400-415

3ph

50

3,00

80

696

64,0

61,0

85,0

1842 x 3660

x1000/810

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50~130(200)

-10~+52

-25 ~ +18

380-400-415

3ph

50

4,00

80

688

64,0

61,0

85,0

1842 x 3250

x1000/795

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

22,20 / 46,3536

50~130(200)

-10~+52

-25 ~ +18

Portata d'aria

Pressione sonora

Potenza sonora

Dimensioni /

Peso netto

Diametro delle

tubazioni

2)

Normale

Modalità silenziosa

Modalità normale

A xL xP

Liquido

Gas

Bilanciamento

m3/min

dB(A)

dB(A)

dB(A)

mm / kg

Pollici (mm)

Pollici (mm)

Pollici (mm)

kg / T

%

°C

°C

Refrigerante (R410A) / CO

2

Eq.

Rapporto di capacità interna/esterna

massimo consentito

3)

Campo di

Raffresc. Min ~ Max

funzionamento

Riscald. Min ~ Max

56

I dati sono indicativi. 1) Il calcolo di EER e COP è basato sulla norma EN14511. 2) Diametro delle tubazioni inferiore a 90 m per l'unità interna finale / superiore a 90 m per l'unità interna finale (se la lunghezza

equivalente delle tubazioni supera i 90 m, aumentare le dimensioni dei tubi principali di 1 livello per i tubi del gas e i tubi del liquido). 3) Se sono soddisfatte le seguenti condizioni, l'intervallo effettivo è

superiore al 130% e inferiore al 200%: A. Rispettare il numero limite di unit

à interne collegabili. B. Il limite inferiore del campo di funzionamento per la temperatura esterna di riscaldamento è limitato a -10 °C

B.U. (standard -25 °C B.U.). C. Il funzionamento simultaneo

è limitato a meno del 130% delle unità interne collegabili.