INDICE SISTEMI VRF

R410A

SISTEMI VRF

HP

42 HP

U-10ME2E8

U-16ME2E8

U-16ME2E8

380-400-415

3ph

50

44 HP

U-12ME2E8

U-16ME2E8

U-16ME2E8

380-400-415

3ph

50

46 HP

48 HP

50 HP

U-14ME2E8

U-16ME2E8

U-10ME2E8

U-16ME2E8

U-16ME2E8

U-12ME2E8

U-16ME2E8

U-16ME2E8

U-12ME2E8

52 HP

U-12ME2E8

U-12ME2E8

U-12ME2E8

U-16ME2E8

380-400-415

3ph

50

5,00

80

928

66,0

63,0

87,0

1842x4900

x1000/1125

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

33,20 / 69,3216

50~130(200)

-10~+52

-25~+18

64 HP

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

380-400-415

3ph

50

8,00

80

928

67,0

64,0

88,0

1842 x 4900

x1000/1260

3/4 (19,05) /

7/8 (22,22)

1-5/8 (41,28) /

1-3/4 (44,45)

1/4 (6,35)

33,20 / 69,3216

50~130(200)

-10~+52

-25 ~ +18

Unità esterna

Tensione

V

Hz

380-400-415

3ph

50

6,00

80

696

65,5

62,5

86,5

1842x3660

x1000/945

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50~130(200)

-10~+52

-25~+18

58 HP

380-400-415

3ph

50

6,00

80

696

66,0

63,0

87,0

1842x3660

x1000/945

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50~130(200)

-10~+52

-25~+18

60 HP

U-16ME2E8

380-400-415

3ph

50

5,00

80

920

65,5

62,5

86,5

1842x4490

x1000/1065

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

30,50 / 63,6840

50~130(200)

-10~+52

-25~+18

62 HP

Alimentazione

Fase

Frequenza

Corrente di avviamento

Pressione statica esterna (max.)

A

5,00

5,00

Pa

80

80

m3/min

688

696

dB(A)

65,0

65,5

dB(A)

62,0

62,5

dB(A)

86,0

86,5

Capacità di raffresc.

kW

118,0

124,0

130,0

135,0

140,0

145,0

EER

1)

W/W

3,69

3,62

3,62

3,52

3,87

3,82

Corrente

A

52,80 - 50,20 - 48,40

56,00 - 53,20 - 51,30

59,90 - 56,90 - 54,90

63,40 - 60,20 - 58,10

59,10 - 56,20 - 54,20

62,10 - 59,00 - 56,80

Potenza d'ingresso

kW

32,00

34,30

35,90

38,40

36,20

38,00

Capacità di riscald.

kW

132,0

138,0

145,0

150,0

155,0

160,0

COP

1)

W/W

4,49

4,50

4,46

4,42

4,65

4,66

Corrente

A

49,10 - 46,60 - 44,90

50,70 - 48,20 - 46,40

54,30 - 51,50 - 49,70

56,60 - 53,80 - 51,80

55,00 - 52,20 - 50,40

56,60 - 53,80 - 51,90

Potenza d'ingresso

kW

29,40

30,70

32,50

33,90

33,30

34,30

Portata d'aria

Pressione sonora

Potenza sonora

Dimensioni /

Peso netto

Diametro delle

tubazioni

2)

Normale

Modalità silenziosa

Modalità normale

A xL x P

Liquido

Gas

Bilanciamento

mm / kg

Pollici (mm)

Pollici (mm)

Pollici (mm)

1842x3250

x1000/840

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

22,20 / 51,9912

50~130(200)

-10~+52

-25~+18

54 HP

U-10ME2E8

U-12ME2E8

U-16ME2E8

U-16ME2E8

380-400-415

3ph

50

6,00

80

920

66,0

63,0

87,0

1842 x 4490

x1000/1110

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

30,50 / 63,6840

50~130(200)

-10~+52

-25 ~ +18

1842x3660

x1000/900

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

24,90 / 51,9912

50~130(200)

-10~+52

-25~+18

56 HP

U-12ME2E8

U-12ME2E8

U-16ME2E8

U-16ME2E8

380-400-415

3ph

50

6,00

80

928

66,5

63,5

87,5

1842 x 4900

x1000/1170

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

33,20 / 69,3216

50~130(200)

-10~+52

-25 ~ +18

Refrigerante (R410A) / CO

2

Eq.

Rapporto di capacità interna/esterna

massimo consentito

3)

kg

%

°C

°C

V

Hz

A

Pa

/T

Campo di

funzionamento

HP

Unità esterna

Alimentazione

Raffresc. Min ~ Max

Riscald. Min ~ Max

Tensione

Fase

Frequenza

U-10ME2E8

U-12ME2E8

U-14ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

U-16ME2E8

Capacità di raffresc.

kW

151,0

156,0

162,0

168,0

174,0

180,0

EER

1)

W/W

3,75

3,71

3,65

3,60

3,60

3,52

Corrente

A

66,60 - 63,20 - 60,90

68,80 - 65,30 - 63,00

73,30 - 69,70 - 67,10

77,10 - 73,30 - 70,60

79,80 - 75,80 - 73,00

84,60 - 80,30 - 77,40

Potenza d'ingresso

kW

40,30

42,10

44,40

46,70

48,30

51,20

Capacità di riscald.

kW

169,0

175,0

182,0

189,0

195,0

201,0

COP

1)

W/W

4,56

4,56

4,47

4,47

4,45

4,42

Corrente

A

61,90 - 58,80 - 56,70

63,40 - 60,20 - 58,10

68,00 - 64,60 - 62,20

70,60 - 67,10 - 64,70

73,10 - 69,50 - 67,00

76,00 - 72,20 - 69,60

Potenza d'ingresso

kW

37,10

38,40

40,70

42,30

43,80

45,50

Corrente di avviamento

Pressione statica esterna (max.)

380-400-415

3ph

50

7,00

80

920

66,5

63,5

87,5

1842 x 4490

x1000/1155

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

30,50 / 63,6840

50~130(200)

-10~+52

-25 ~ +18

380-400-415

3ph

50

7,00

80

928

67,0

64,0

88,0

1842 x 4900

x1000/1215

3/4 (19,05) /

7/8 (22,22)

1-1/2 (38,10) /

1-5/8 (41,28)

1/4 (6,35)

33,20 / 69,3216

50~130(200)

-10~+52

-25 ~ +18

380-400-415

3ph

50

8,00

80

928

67,0

64,0

88,0

1842 x 4900

x1000/1260

3/4 (19,05) /

7/8 (22,22)

1-5/8 (41,28) /

1-3/4 (44,45)

1/4 (6,35)

33,20 / 69,3216

50~130(200)

-10~+52

-25 ~ +18

Portata d'aria

Pressione sonora

Potenza sonora

Dimensioni /

Peso netto

Diametro delle

tubazioni

2)

Normale

Modalità silenziosa

Modalità normale

A xL x P

Liquido

Gas

Bilanciamento

m3/min

dB(A)

dB(A)

dB(A)

mm / kg

Pollici (mm)

Pollici (mm)

Pollici (mm)

kg / T

%

°C

°C

Refrigerante (R410A) / CO

2

Eq.

Rapporto di capacità interna/esterna

massimo consentito

3)

Campo di

Raffresc. Min ~ Max

funzionamento

Riscald. Min ~ Max

I dati sono indicativi. 1) Il calcolo di EER e COP è basato sulla norma EN14511. 2) Diametro delle tubazioni inferiore a 90 m per l'unità interna finale / superiore a 90 m per l'unità interna finale (se la lunghezza

equivalente delle tubazioni supera i 90 m, aumentare le dimensioni dei tubi principali di 1 livello per i tubi del gas e i tubi del liquido). 3) Se sono soddisfatte le seguenti condizioni, l'intervallo effettivo è

superiore al 130% e inferiore al 200%: A. Rispettare il numero limite di unità interne collegabili. B. Il limite inferiore del campo di funzionamento per la temperatura esterna di riscaldamento è limitato a -10 °C

B.U. (standard -25 °C B.U.). C. Il funzionamento simultaneo è limitato a meno del 130% delle unità interne collegabili.

Condizioni nominali: Raffrescamento interno 27 °C B.S. / 19 °C B.U. Raffrescamento esterno 35 °C B.S. / 24 °C B.U. Riscaldamento interno 20 °C B.S. Riscaldamento esterno 7 °C B.S. / 6 °C B.U. (B.S.: Bulbo Secco; B.U.: Bulbo Umido).

Le specifiche sono soggette a modifiche senza preavviso. Per informazioni dettagliate su ErP / Etichette energetiche, visitate i nostri siti web www.aircon.panasonic.eu o www.ptc.panasonic.eu.

57