HP
Unità esterna
Alimentazione
22 HP
U-10ME2E8
U-12ME2E8
380-400-415
3ph
50
2,00
80
456
dB(A)
dB(A)
82,0
83,0
83,5
84,5
84,5
85,0
84,0
Tensione
Fase
Frequenza
V
Hz
A
Pa
m3/min
24 HP
U-12ME2E8
U-12ME2E8
380-400-415
3ph
50
2,00
80
464
26 HP
U-10ME2E8
U-16ME2E8
380-400-415
3ph
50
3,00
80
456
28 HP
U-12ME2E8
U-16ME2E8
380-400-415
3ph
50
3,00
80
464
30 HP
U-14ME2E8
U-16ME2E8
380-400-415
3ph
50
4,00
80
464
32 HP
U-16ME2E8
U-16ME2E8
380-400-415
3ph
50
4,00
80
464
34 HP
U-14ME2E8
U-20ME2E8
380-400-415
3ph
50
4,00
80
637
Capacità di raffresc.
kW
61,5
68,0
73,0
78,5
85,0
90,0
96,0
EER
1)
W/W
4,13
3,93
3,80
3,69
3,68
3,52
3,56
SEER
2)
6,90
6,86
6,62
6,60
6,88
6,55
7,21
Corrente
A
24,30 - 23,10 -
22,30
28,00 - 26,60 -
25,60
31,70 - 30,10 -
29,00
34,80 - 33,10 -
31,90
38,60 - 36,60 -
35,30
42,30 - 40,20 -
38,70
44,10 - 41,90 -
40,40
Potenza d'ingresso
kW
14,90
17,30
19,20
21,30
23,10
25,60
27,00
Capacità di riscald.
kW
69,0
76,5
81,5
87,5
95,0
100,0
108,0
COP
1)
W/W
4,76
4,69
4,55
4,56
4,48
4,42
4,17
SCOP
2)
4,53
4,78
4,16
4,29
4,13
4,09
4,14
Corrente
A
23,90 - 22,70 -
21,90
26,60 - 25,30 -
24,40
29,90 - 28,40 -
27,40
31,70 - 30,10 -
29,00
35,40 - 33,60 -
32,40
37,70 - 35,80 -
34,60
42,80 - 40,60 -
39,20
Potenza d'ingresso
kW
14,50
16,30
17,90
19,20
21,20
22,60
25,90
Corrente di avviamento
Pressione statica esterna (max.)
Portata d'aria
Pressione sonora
Potenza sonora
Dimensioni /
Peso netto
Diametro delle
tubazioni
3)
Modalità normale /
silenziosa
Modalità normale
A xL xP
Liquido
Gas
61,0 / 58,0
62,0 / 59,0
62,5 / 59,5
63,5 / 60,5
63,5 / 60,5
64,0 / 61,0
63,0 / 60,0
Bilanciamento
Refrigerante (R410A) / CO
2
Eq.
Rapporto di capacità interna/esterna
mm / kg
Pollici (mm)
Pollici (mm)
Pollici (mm)
kg / T
%
°C
°C
V
Hz
A
Pa
m3/min
dB(A)
dB(A)
mm / kg
Pollici (mm)
Pollici (mm)
Pollici (mm)
kg / T
%
°C
°C
1842x2010
x1000/480
5/8 (15,88) /
3/4 (19,05)
1-1/8 (28,58) /
1-1/4 (31,75)
1/4 (6,35)
13,90 / 23,3856
50~130(200)
-10~+52
-25~+18
36 HP
U-16ME2E8
U-20ME2E8
380-400-415
3ph
50
4,00
80
637
63,5 / 60,5
84,5
1842 x 2780
x1000/690
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
17,80 / 37,1664
50~130(200)
-10~+52
-25~+18
1842x2420
x1000/540
5/8 (15,88) /
3/4 (19,05)
1-1/8 (28,58) /
1-1/4 (31,75)
1/4 (6,35)
16,60 / 34,6608
50~130(200)
-10~+52
-25~+18
38 HP
U-18ME2E8
U-20ME2E8
380-400-415
3ph
50
4,00
80
810
62,5 / 59,5
83,5
1842 x 3140
x1000/750
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
19,00 / 39.672
50~130(200)
-10~+52
-25~+18
1842x2010
x1000/525
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
13,90 / 29,0232
50~130(200)
-10~+52
-25~+18
40 HP
U-20ME2E8
U-20ME2E8
380-400-415
3ph
50
4,00
80
810
63,0 / 60,0
84,0
1842 x 3140
x1000/750
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
19,00 / 39.672
50~130(200)
-10~+52
-25~+18
1842x2420
x1000/585
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
16,60 / 34,6608
50~130(200)
-10~+52
-25~+18
42 HP
U-10ME2E8
U-16ME2E8
U-16ME2E8
380-400-415
3ph
50
5,00
80
688
65,0 / 62,0
86,0
1842 x 3250
x1000/840
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
22,20 / 46,3536
50~130(200)
-10~+52
-25~+18
1842x2420
x1000/630
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
16,60 / 34,6608
50~130(200)
-10~+52
-25~+18
44 HP
U-12ME2E8
U-16ME2E8
U-16ME2E8
380-400-415
3ph
50
5,00
80
696
65,5 / 62,5
86,5
1842 x 3660
x1000/900
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50~130(200)
-10~+52
-25~+18
1842x2420
x1000/630
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
16,60 / 34,6608
50~130(200)
-10~+52
-25~+18
46 HP
U-14ME2E8
U-16ME2E8
U-16ME2E8
380-400-415
3ph
50
6,00
80
696
65,5 / 62,5
86,5
1842 x 3660
x1000/945
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50~130(200)
-10~+52
-25~+18
1842x2780
x1000/690
3/4 (19,05) /
7/8 (22,22)
1-1/4 (31,75) /
1-1/2 (38,10)
1/4 (6,35)
17,80 / 37,1664
50~130(200)
-10~+52
-25~+18
48 HP
U-16ME2E8
U-16ME2E8
U-16ME2E8
380-400-415
3ph
50
6,00
80
696
66,0 / 63,0
87,0
1842 x 3660
x1000/945
3/4 (19,05) /
7/8 (22,22)
1-1/2 (38,10) /
1-5/8 (41,28)
1/4 (6,35)
24,90 / 51,9912
50~130(200)
-10~+52
-25~+18
massimo consentito
4)
Campo di
funzionamento
HP
Unità esterna
Alimentazione
Raffresc. Min ~ Max
Riscald. Min ~ Max
Tensione
Fase
Frequenza
Capacità di raffresc.
kW
101,0
107,0
113,0
118,0
124,0
130,0
135,0
EER
1)
W/W
3,42
3,42
3,34
3,69
3,62
3,62
3,52
SEER
2)
6,86
7,32
7,16
6,57
6,60
6,70
6,55
Corrente
A
47,70 - 45,30 -
43,70
50,60 - 48,10 -
46,30
54,10 - 51,40 -
49,50
52,80 - 50,20 -
48,40
56,00 - 53,20 -
51,30
59,90 - 56,90 -
54,90
63,40 - 60,20 -
58,10
Potenza d'ingresso
kW
25,9
31,3
33,8
32,0
34,3
35,9
38,4
Capacità di riscald.
kW
113,0
119,0
127,0
132,0
138,0
145,0
150,0
COP
1)
W/W
4,14
4,13
3,92
4,49
4,50
4,46
4,42
SCOP
2)
4,06
4,14
4,13
4,11
4,21
4,12
4,09
Corrente
A
44,60 - 42,40 -
40,80
47,10 - 44,70 -
43,10
52,40 - 49,80 -
48,00
49,10 - 46,60 -
44,90
50,70 - 48,20 -
46,40
54,30 - 51,50 -
49,7
56,60 - 53,80 -
51,8
Potenza d'ingresso
kW
27,30
28,80
32,40
29,40
30,70
32,50
33,90
Corrente di avviamento
Pressione statica esterna (max.)
Portata d'aria
Pressione sonora
Potenza sonora
Dimensioni /
Peso netto
Diametro delle
tubazioni
3)
Modalità normale /
silenziosa
Modalità normale
A xL xP
Liquido
Gas
Bilanciamento
Refrigerante (R410A) / CO
2
Eq.
Rapporto di capacità interna/esterna
massimo consentito
4)
Campo di
Raffresc. Min ~ Max
funzionamento
Riscald. Min ~ Max
58
1) Il calcolo di EER e COP è basato sulla norma EN14511. 2) I valori SEER / SCOP sono calcolati in base ai valori di efficienza stagionale di raffrescamento/riscaldamento degli ambienti “η” del REGOLAMENTO
DELLA COMMISSIONE (UE) 2016/2281. SEER, SCOP = (η + Correzione) × PEF. 3) Diametro delle tubazioni inferiore a 90 m per l'unità interna finale / superiore a 90 m per l'unità interna finale (se la lunghezza
equivalente delle tubazioni supera i 90 m, aumentare le dimensioni dei tubi principali di 1 livello per i tubi del gas e i tubi del liquido). 4) Se sono soddisfatte le seguenti condizioni, l'intervallo effettivo è
superiore al 130% e inferiore al 200%: A. Rispettare il numero limite di unit
à interne collegabili. B. Il limite inferiore del campo di funzionamento per la temperatura esterna di riscaldamento è limitato a -10 °C
B.U. (standard -25 °C B.U.). C. Il funzionamento simultaneo
è limitato a meno del 130% delle unità interne collegabili.