Required space for service and ventilation
Indoor air flow
Left side
Rear side
Rear side
Right side
Wireless remote control
Blade angle
Up/down (automatic)
Bottom side
Flap
Signal receiver
Operation lamp
Timer lamp
Intelligent Eye lamp
Intelligent Eye sensor
Indoor unit On/OFF switch
Room temperature sensor
Located inside of the unit
Drain hose Connecting part
Inside diameter: ·
U
14·mm
Outside diameter: ·
U
16·mm
The length of the connection hose outside
the unit is ·470·mm.
Liquid pipe
·
U
6.4· CuT
(ARC466A67)
Signal transmitter
58.5
23.5
Cooling
5°
Fan
0°
Heating
65°
Dry
45°
The length of the pipe outside
the unit is ·410·mm.
778
Front grille fixing screws
Located inside of the unit
Nameplate
Located inside
of the unit
Bottom side
272
269.3
131.1
50 MIN
Terminal block with earth terminal
Located inside of the unit
Gas pipe
·
U
9.5· CuT
The length of the pipe outside
the unit is ·360·mm.
Air outlet
50 MIN
45°
15°
5°
Standard location of holes in the wall
Including mounting plate
Minimum space for air passage
120
120
536.6
4
5
v
45v
45v
45v
O80
O
8
0
5
2
2
9
9
1
4
.
4
5
2
1
8
9
2
1
.
1
2
3
.
3
3
0
2
9
9
3
5
.
3
2
9
5
S
e
r
v
i
c
e
s
p
a
c
e
S
e
r
v
i
c
e
s
p
a
c
e
3
0
M
I
N
3
0
M
I
N
4
4
.
5
4
4
.
5
2
9
5
1
8
9
1
6
.
6
S
e
r
v
i
c
e
s
p
a
c
e
S
e
r
v
i
c
e
s
p
a
c
e
10
Left side
Applicable models
FTXM50R2V1B/FTXM60R2V1B
Rear side
Rear side
Required space for service and ventilation
Indoor air flow
Minimum space for air passage
Air outlet
Bottom side
Flap
Terminal block with earth terminal
Located inside of the unit
Gas pipe
·
U
12.7 mm· CuT
The length of the pipe outside the unit
is ·400·mm.
Liquid pipe
·
U
6.4 mm· CuT
The length of the pipe outside
the unit is ·460·mm.
Drain hose Connecting part
Inside diameter: ·
U
14·mm
Outside diameter: ·
U
16·mm
The length of the connection hose
outside the unit is ·440·mm.
Wireless remote control
(ARC466A67)
Signal transmitter
58.5
23.5
Signal receiver
Operation lamp
Timer lamp
Intelligent Eye sensor
Intelligent Eye lamp
Indoor unit On/OFF switch
Room temperature sensor
Located inside of the unit
Blade angle
Up/down (automatic)
998
ATXM50R2V1B
Front grille fixing screws
Located inside of the unit
292
289.1
184.7
10°
5°
25°
Fan
15°
65°
55°
75°
15°
10°
25°
65°
Dry
45°
Standard location of holes in the wall
Cooling
Heating
45°
75°
20°
55°
998
746.6
Left/right (automatic)
Hole for embedded piping
65°
Left/right (automatic)
Notes
1T.he ·
53
160
170
53
· mark shows the piping direction.
Hole for embedded piping
Right side
Including mounting plate
Nameplate
Located inside
of the unit
Bottom side
50 MIN
50 MIN
53
170
170
65
120.5
O65
O65
778
130